Sec. 192.150  Passage of internal inspection devices.

    (a) Except as provided in paragraphs (b) and (c) of this section, 
each new transmission line and each line section of a transmission line 
where the line pipe, valve, fitting, or other line component is replaced 
must be designed and constructed to accommodate the passage of 
instrumented internal inspection devices.
    (b) This section does not apply to: (1) Manifolds;
    (2) Station piping such as at compressor stations, meter stations, 
or regulator stations;
    (3) Piping associated with storage facilities, other than a 
continuous run of transmission line between a compressor station and 
storage facilities;
    (4) Cross-overs;
    (5) Sizes of pipe for which an instrumented internal inspection 
device is not commercially available;
    (6) Transmission lines, operated in conjunction with a distribution 
system which are installed in Class 4 locations;
    (7) Offshore pipelines, other than transmission lines 10 inches (254 
millimeters) or greater in nominal diameter, that transport gas to 
onshore facilities; and
    (8) Other piping that, under Sec. 190.9 of this chapter, the 
Administrator finds in a particular case would be impracticable to 
design and construct to accommodate the passage of instrumented internal 
inspection devices.
    (c) An operator encountering emergencies, construction time 
constraints or other unforeseen construction problems need not construct 
a new or replacement segment of a transmission line to meet paragraph 
(a) of this section, if the operator determines and documents why an 
impracticability prohibits compliance with paragraph (a) of this 
section. Within 30 days after discovering the emergency or construction 
problem the operator must petition, under Sec. 190.9 of this chapter, 
for approval that design and construction to accommodate passage of 
instrumented internal inspection devices would be impracticable. If the 
petition is denied, within 1 year after the date of the notice of the 
denial, the operator must modify that segment to allow

[[Page 42]]

passage of instrumented internal inspection devices.