Sec. 229.23  Periodic inspection: General.

    (a) Each locomotive and steam generator shall be inspected at each 
periodic inspection to determine whether it complies with this part. 
Except as provided in Sec. 229.9, all non-complying conditions shall be 
repaired before the locomotive or the steam generator is used. Except as 
provided in Sec. 229.33, the interval between any two periodic 
inspections may not exceed 92 days. Periodic inspections shall only be 
made where adequate facilities are available. At each periodic 
inspection, a locomotive shall be positioned so that a person may safely 
inspect the entire underneath portion of the locomotive.
    (b) The periodic inspection of the steam generator may be postponed 
indefinitely if the water suction pipe to the water pump and the leads 
to the main switch (steam generator switch) are disconnected, and the 
train line shut-off-valve is wired closed or a blind gasket applied. 
However, the steam generator shall be so inspected before it is returned 
to use.
    (c) After April 30, 1980, each new locomotive shall receive an 
initial periodic inspection before it is used. Except as provided in 
Sec. 229.33, each locomotive in use on or before April 30, 1980, shall 
receive an initial periodic inspection within 92 days of the last 30-day 
inspection performed under the prior rules (49 CFR 230.331 and 230.451). 
At the initial periodic inspection, the date and place of the last tests 
performed that are the equivalent of the tests required by Secs. 229.27, 
229.29, and 229.31 shall be entered on Form FRA F 6180-49A. These dates 
shall determine when the tests first become due under Secs. 229.27, 
229.29, and 229.31. Out of use credit may be carried over from Form FRA 
F 6180-49 and entered on Form FRA F 6180-49A.
    (d) Each periodic inspection shall be recorded on Form FRA F 6180-
49A. The form shall be signed by the person conducting the inspection 
and certified by that person's supervisor that the work was done. The 
form shall be displayed under a transparent cover in a conspicuous place 
in the cab of each locomotive.
    (e) At the first periodic inspection in each calendar year the 
carrier shall remove from each locomotive Form FRA F 6180-49A covering 
the previous calendar year. If a locomotive does not receive its first 
periodic inspection in a calendar year before April 2 because it is out 
of use, the form shall be promptly replaced. The Form FRA F 6180-49A 
covering the preceding year for each locomotive, in or out of use, shall 
be signed by the railroad official responsible for the locomotive and 
filed as required in Sec. 229.23(f). The date and place of the last 
periodic inspection and the date and place of the last test performed 
under Secs. 229.27, 229.29, and 229.31 shall be transferred to the 
replacement Form FRA F 6180-49A.
    (f) The mechanical officer of each railroad who is in charge of a 
locomotive shall maintain in his office a secondary record of the 
information reported on Form FRA F 6180-49A under this part. The 
secondary record shall be retained until Form FRA F 6180-49A has been 
removed from the locomotive and filed in the railroad office of the 
mechanical officer in charge of the locomotive. If the Form FRA F 6180-
49A removed from the locomotive is not clearly legible, the secondary 
record shall be retained until the Form FRA F 6180-49A for the 
succeeding year is filed. The Form F 6180-49A removed from a locomotive 
shall be retained until the Form FRA F 6180-49A for the succeeding year 
is filed.

[45 FR 21109, Mar. 31, 1980, as amended at 45 FR 39852, June 12, 1980; 
50 FR 6953, Feb. 19, 1985]