Sec. 236.106  Relays.

    Each relay, the functioning of which affects the safety of train 
operations, shall be tested at least once every four years except:
    (a) Alternating current centrifugal type relay shall be tested at 
least once every 12 months;
    (b) Alternating current vane type relay and direct current polar 
type relay shall be tested at least once every 2 years; and
    (c) Relay with soft iron magnetic structure shall be tested at least 
once every 2 years.