    (a) This section applies to each passenger car ordered on or after 
September 8, 2000, or placed in service for the first time on or after 
September 9, 2002. This section applies to each level of a multi-level 
passenger car.
    (b) Emergency lighting shall be provided in each passenger car and 
shall include the following:
    (1) A minimum, average illumination level of 1 foot-candle measured 
at floor level adjacent to each exterior door and each interior door 
providing access to an exterior door (such as a door opening into a 
vestibule);
    (2) A minimum, average illumination level of 1 foot-candle measured 
25 inches above floor level along the center of each aisle and 
passageway;
    (3) A minimum illumination level of 0.1 foot-candle measured 25 
inches above floor level at any point along the center of each aisle and 
passageway; and
    (4) A back-up power system capable of:
    (i) Operating in all equipment orientations within 45 degrees of 
vertical;
    (ii) Operating after the initial shock of a collision or derailment 
resulting in the following individually applied accelerations:
    (A) Longitudinal: 8g;
    (B) Lateral: 4g; and
    (C) Vertical: 4g; and
    (iii) Operating all emergency lighting for a period of at least 90 
minutes without a loss of more than 40% of the minimum illumination 
levels specified in this paragraph (b).