[Code of Federal Regulations]
[Title 50, Volume 6]
[Revised as of October 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 50CFR223.207]

[Page 170-178]
 
                    TITLE 50--WILDLIFE AND FISHERIES
 
                      SERVICE, NATIONAL OCEANIC AND
                       ATMOSPHERIC ADMINISTRATION,
                         DEPARTMENT OF COMMERCE
 
PART 223--THREATENED MARINE AND ANADROMOUS SPECIES--Table of Contents
 
 Subpart B--Restrictions Applicable to Threatened Marine and Anadromous 
                                 Species
 
Sec. 223.207  Approved TEDs.

    Any netting, webbing, or mesh that may be measured to determine 
compliance with this section is subject to measurement, regardless of 
whether it is wet or dry. Any such measurement will be of the stretched 
mesh size.
    (a) Hard TEDs. Hard TEDs are TEDs with rigid deflector grids and are 
categorized as ``hooped hard TEDs'' and ``single-grid hard TEDs'' such 
as the Matagorda and Georgia TED (Figures 3 & 4 to this part). Hard TEDs 
complying with the following generic design criteria are approved TEDs:
    (1) Construction materials--(i) Single-grid and inshore hooped hard 
TED. A single-grid hard TED or an inshore hooped hard TED must be 
constructed of one or a combination of the following materials, with 
minimum dimensions as follows:
    (A) Solid steel rod with a minimum outside diameter of 1/4 inch 
(0.64 cm);
    (B) Fiberglass or aluminum rod with a minimum outside diameter of 1/
2 inch (1.27 cm); or
    (C) Steel or aluminum tubing with a minimum outside diameter of 1/2 
inch (1.27 cm) and a minimum wall thickness of 1/8 inch (0.32 cm) (also 
known as schedule 40 tubing).
    (ii) Offshore hooped hard TED. An offshore hooped hard TED must be 
constructed of aluminum, with minimum dimensions as follows:
    (A) Solid rod with a minimum outside diameter of 5/8 inch (1.59 cm); 
or
    (B) Tubing with a minimum outside diameter of 1 inch (2.54 cm) and a 
minimum wall thickness of 1/8 inch (0.32 cm).
    (2) Method of attachment. A hard TED must be sewn into the trawl 
around the entire circumference of the TED with heavy twine.
    (3) Angle of deflector bars. (i) The angle of the deflector bars 
must be between 30[deg] and 55[deg] from the normal, horizontal flow 
through the interior of the trawl, except as provided in paragraph 
(a)(3)(ii) of this section.
    (ii) For any shrimp trawler fishing in the Gulf SFSTCA or the 
Atlantic SFSTCA, a hard TED with the position of the escape opening at 
the bottom of the net when the net is in its deployed position, the 
angle of the deflector bars from the normal, horizontal flow through the 
interior of the trawl, at any point, must not exceed 55[deg], and the 
angle of the bottom-most 4 inches (10.2 cm) of each deflector bar, 
measured along the bars, must not exceed 45[deg] (Figures 14a and 14b to 
this part).
    (4) Space between bars. The space between deflector bars and the 
deflector bars and the TED frame must not exceed 4 inches (10.2 cm).
    (5) Direction of bars. The deflector bars must run from top to 
bottom of the TED, as the TED is positioned in

[[Page 171]]

the net, except that up to four of the bottom bars and two of the top 
bars, including the frame, may run from side to side of the TED. The 
deflector bars must be permanently attached to the TED frame or to the 
horizontal bars, if used, at both ends.
    (6) Position of the escape opening. The escape opening must be made 
by removing a rectangular section of webbing from the trawl, except for 
a TED with an escape opening size described at paragraph (a)(7)(ii)(A) 
for which the escape opening may alternatively be made by making a 
horizontal cut along the same plane as the TED. The escape opening must 
be centered on and immediately forward of the frame at either the top or 
bottom of the net when the net is in the deployed position. The escape 
opening must be at the top of the net when the slope of the deflector 
bars from forward to aft is upward, and must be at the bottom when such 
slope is downward. The passage from the mouth of the trawl through the 
escape opening must be completely clear of any obstruction or 
modification, other than those specified in paragraph (d) of this 
section.
    (7) Size of escape opening-- (i) Hooped hard TEDs--(A) Escape 
opening for inshore hooped hard TED. The inshore hooped hard TED escape 
opening must have a horizontal measurement of no less than 35 inches (89 
cm) wide and a forward measurement of no less than 27 inches (69 cm). A 
hinged door frame may be used to partially cover the escape opening as 
provided in paragraph (d)(7) of this section. Alternatively, a webbing 
flap may be used as provided in paragraph (d)(3)(i) of this section. The 
resultant opening with a webbing flap must be a minimum width of 35 
inches (89 cm) and a minimum height of 20 inches (51 cm), with each 
measurement taken simultaneously. This opening may only be used in 
inshore waters, except it may not be used in the inshore waters of 
Georgia and South Carolina.
    (B) Escape opening for offshore hooped hard TED. The offshore hooped 
hard TED escape opening must have a horizontal measurement of no less 
than 40 inches (102 cm) wide and a forward measurement of no less than 
35 inches (89 cm). A hinged door frame may be used to partially cover 
the escape opening as provided in paragraph (d)(7) of this section. 
Alternatively, a webbing flap may be used as provided in paragraph 
(d)(3)(ii) of this section. The resultant escape opening with a webbing 
flap must have a stretched mesh circumference of no less than 142 inches 
(361 cm).
    (ii) Single-grid hard TEDs. On a single-grid hard TED, the 
horizontal cut(s) for the escape opening may not be narrower than the 
outside width of the TED frame minus 4 inches (10.2 cm) on both sides of 
the grid, when measured as a straight line width. Fore-and-aft cuts to 
remove a rectangular piece of webbing must be made from the ends of the 
horizontal cuts along a single row of meshes along each side. The 
overall size of the escape opening must match one of the following 
specifications:
    (A) 44-inch inshore opening. The escape opening must have a minimum 
width of 44 inches (112 cm) and a minimum height of 20 inches (51 cm) 
with each measurement taken separately. A webbing flap, as described in 
paragraph (d)(3)(i) of this section, may be used with this escape hole, 
so long as this minimum opening size is achieved. This opening may only 
be used in inshore waters, except it may not be used in the inshore 
waters of Georgia and South Carolina.
    (B) The 71-inch offshore opening: The two forward cuts of the escape 
opening must not be less than 26 inches (66 cm) long from the points of 
the cut immediately forward of the TED frame. The resultant length of 
the leading edge of the escape opening cut must be no less than 71 
inches (181 cm) with a resultant circumference of the opening being 142 
inches (361 cm) (Figure 12 to this part). A webbing flap, as described 
in paragraph (d)(3)(ii) of this section, may be used with this escape 
hole, so long as this minimum opening size is achieved. Either this 
opening or the one described in paragraph (a)(7)(ii)(C) of this section 
must be used in all offshore waters and in all inshore waters in Georgia 
and South Carolina, but may also be used in other inshore waters.
    (C) Double cover offshore opening. The two forward cuts of the 
escape opening must not be less than 20 inches (51 cm)

[[Page 172]]

long from the points of the cut immediately forward of the TED frame. 
The resultant length of the leading edge of the escape opening cut must 
be no less than 56 inches (142 cm)(Figure 16 to this part illustrates 
the dimensions of these cuts). A webbing flap, as described in paragraph 
(d)(3)(iii) of this section, may be used with this escape hole. Either 
this opening or the one described in paragraph (a)(7)(ii)(B) of this 
section must be used in all offshore waters but also in all inshore 
waters in Georgia and South Carolina, and may be used in other inshore 
waters.
    (8) Size of hoop or grid--(i) Hooped hard TED--(A) Inshore hooped 
hard TED. The front hoop on an inshore hooped hard TED must have an 
inside horizontal measurement of at least 35 inches (89 cm) and an 
inside vertical measurement of at least 30 inches (76 cm). The minimum 
clearance between the deflector bars and the forward edge of the escape 
opening must be at least 20 inches (51 cm).
    (B) Offshore hooped hard TED. The front hoop on an offshore hooped 
hard TED must have an inside horizontal measurement of at least 40 
inches (102 cm) and an inside vertical measurement of at least 30 inches 
(76 cm). The minimum clearance between the deflector bars and the 
forward edge of the escape opening must be at least 23 1/4 inches (59 
cm).
    (ii) Single-grid hard TED. A single-grid hard TED must have a 
minimum outside horizontal and vertical measurement of 32 inches (81 
cm). The required outside measurements must be at the mid-point of the 
deflector grid.
    (9) Flotation. Floats must be attached to the top one-half of all 
hard TEDs with bottom escape openings. The floats may be attached either 
outside or inside the net, but not to a flap. Floats attached inside the 
net must be behind the rear surface of the TED. Floats must be attached 
with heavy twine or rope. Floats must be constructed of aluminum, hard 
plastic, expanded polyvinyl chloride, or expanded ethylene vinyl acetate 
unless otherwise specified. The requirements of this paragraph may be 
satisfied by compliance with either the dimension requirements of 
paragraph (a)(9)(i) of this section, or the buoyancy requirements of 
paragraph (a)(9)(ii) of this section, or the buoyancy-dimension 
requirements of paragraph (a)(9)(iii) of this section. If roller gear is 
used pursuant to paragraph (d)(5) of this section, the roller gear must 
be included in the circumference measurement of the TED or the total 
weight of the TED.
    (i) Float dimension requirements. (A) For hard TEDs with a 
circumference of 120 inches (304.8 cm) or more, a minimum of either one 
round, aluminum or hard plastic float, no smaller than 9.8 inches (25.0 
cm) in diameter, or two expanded polyvinyl chloride or expanded ethylene 
vinyl acetate floats, each no smaller than 6.75 inches (17.2 cm) in 
diameter by 8.75 inches (22.2 cm) in length, must be attached.
    (B) For hard TEDs with a circumference of less than 120 inches 
(304.8 cm), a minimum of either one round, aluminum or hard plastic 
float, no smaller than 9.8 inches (25.0 cm) in diameter, or one expanded 
polyvinyl chloride or expanded ethylene vinyl acetate float, no smaller 
than 6.75 inches (17.2 cm) in diameter by 8.75 inches (22.2 cm) in 
length, must be attached.
    (ii) Float buoyancy requirements. Floats of any size and in any 
combination must be attached such that the combined buoyancy of the 
floats, as marked on the floats, equals or exceeds the weight of the 
hard TED, as marked on the TED. The buoyancy of the floats and the 
weight of the TED must be clearly marked on the floats and the TED as 
follows:
    (A) Float buoyancy markings. Markings on floats must be made in 
clearly legible raised or recessed lettering by the original 
manufacturer. The marking must identify the buoyancy of the float in 
water, expressed in grams or kilograms, and must include the metric unit 
of measure. The marking may additionally include the buoyancy in English 
units. The marking must identify the nominal buoyancy for the 
manufactured float.
    (B) TED weight markings. The marking must be made by the original 
TED manufacturer and must be permanent and clearly legible. The marking 
must identify the in-air, dry weight of the TED, expressed in grams or 
kilograms, and must include the metric unit of

[[Page 173]]

measure. The marking may additionally include the weight in English 
units. The marked weight must represent the actual weight of the 
individual TED as manufactured. Previously manufactured TEDs may be 
marked upon return to the original manufacturer. Where a TED is 
comprised of multiple detachable components, the weight of each 
component must be separately marked.
    (iii) Buoyancy-dimension requirements. Floats of any size and in any 
combination, provided that they are marked pursuant to paragraph 
(a)(9)(ii)(A) of this section, must be attached such that the combined 
buoyancy of the floats equals or exceeds the following values:
    (A) For floats constructed of aluminum or hard plastic, regardless 
of the size of the TED grid, the combined buoyancy must equal or exceed 
14 lb (6.4 kg);
    (B) For floats constructed of expanded polyvinyl chloride or 
expanded ethylene vinyl acetate, where the circumference of the TED is 
120 inches (304.8 cm) or more, the combined buoyancy must equal or 
exceed 20 lb (9.1 kg); or
    (C) For floats constructed of expanded polyvinyl chloride or 
expanded ethylene vinyl acetate, where the circumference of the TED is 
less than 120 inches (304.8 cm), the combined buoyancy must equal or 
exceed 10 lb (4.5 kg).
    (b) Special Hard TEDs. Special hard TEDs are hard TEDs which do not 
meet all of the design and construction criteria of the generic 
standards specified in paragraph (a) of this section. The following 
special hard TEDs are approved TEDs:
    (1) Flounder TED. (Figure 10 to this part). The Flounder TED is 
approved for use only in the Atlantic summer flounder bottom trawl 
fishery. The Flounder TED is not an approved TED for use by shrimp 
trawlers. The Flounder TED must be constructed of at least 1 1/4 inch 
(3.2 cm) outside diameter aluminum or steel pipe with a wall thickness 
of at least 1/8 inch (0.3 cm). It must have a rectangular frame with 
outside dimensions which can be no less than 51 inches (129.5 cm) in 
length and 32 inches (81.3 cm) in width. It must have at least five 
vertical deflector bars, with bar spacings of no more than 4 inches 
(10.2 cm). The vertical bars must be connected to the top of the frame 
and to a single horizontal bar near the bottom. The horizontal bar must 
be connected at both ends to the sides of the frame and parallel to the 
bottom bar of the frame. There must be a space no larger than 10 inches 
(25.4 cm) between the horizontal bar and the bottom bar of the frame. 
One or more additional vertical bars running from the bottom bar to the 
horizontal bar must divide the opening at the bottom into two or more 
rectangles, each with a maximum height of 10 inches (25.4 cm) and a 
maximum width of 14 1/2 inches (36.8 cm). This TED must comply with 
paragraph (a)(2) of this section. The angle of the deflector bars must 
be between 30 and 55 from the normal, horizontal flow through the 
interior of the trawl. The entire width of the escape opening from the 
trawl must be centered on and immediately forward of the frame at the 
top of the net when the net is in its deployed position. The escape 
opening must be at the top of the net and the slope of the deflector 
bars from forward to aft is upward. The escape opening must be cut 
horizontally along the same plane as the TED, and may not be cut in a 
fore-and-aft direction. The cut in the trawl webbing for the escape 
opening cannot be narrower than the outside width of the grid minus 4 
inches (10.2 cm) on both sides of the grid, when measured as a straight 
line width. The resulting escape opening in the net webbing must measure 
at least 35 inches (88.9 cm) in horizontal taut length and, 
simultaneously, 12 inches (30.5 cm) in vertical taut height. The 
vertical measurement must be taken at the midpoint of the horizontal 
measurement. This TED may not be configured with a bottom escape 
opening. Installation of an accelerator funnel is not permitted with 
this TED.
    (2) Weedless TED. The weedless TED must meet all the requirements of 
paragraph (a) of this section for single-grid hard TEDs, with the 
exception of paragraphs (a)(1) and (a)(5) of this section. The weedless 
TED must be constructed of at least 1-1/4 inch (3.2 cm) outside diameter 
aluminum with a wall

[[Page 174]]

thickness of at least 1/8 inch (0.3 cm). The deflector bars must run 
from top to bottom of the TED, as the TED is positioned in the net. The 
ends of the deflectors bars on the side of the frame opposite to the 
escape opening must be permanently attached to the frame. The ends of 
the deflector bars nearest the escape opening are not attached to the 
frame and must lie entirely forward of the leading edge of the outer 
frame. The ends of the unattached deflector bars must be no more than 4 
inches (10.2 cm) from the frame and may not extend past the frame. A 
horizontal brace bar to reinforce the deflector bars, constructed of the 
same size or larger pipe as the deflector bars, must be permanently 
attached to the frame and the rear face of each of the deflector bars at 
a position anywhere between the vertical mid-point of the frame and the 
unattached ends of the deflector bars. The horizontal brace bar may be 
offset behind the deflector bars, using spacer bars, not to exceed 5 
inches (12.7 cm) in length and constructed of the same size or larger 
pipe as the deflector bars. See Figure 15.
    (c) Soft TEDs. Soft TEDs are TEDs with deflector panels made from 
polypropylene or polyethylene netting. The following soft TEDs are 
approved TEDs:
    (1) Parker TED. The Parker TED is a soft TED, consisting of a single 
triangular panel, composed of webbing of two different mesh sizes, that 
forms a complete barrier inside a trawl and that angles toward an escape 
opening in the top of the trawl.
    (i) Excluder Panel. (Figure 5 to this part) The excluder panel of 
the Parker TED must be constructed of a single triangular piece of 8-
inch (20.3 cm) stretched mesh webbing and two trapezoidal pieces of 4-
inch (10.2-cm) stretched mesh webbing. The webbing must consist of 
number 48 (3-mm thick) or larger polypropylene or polyethylene webbing 
that is heat-set knotted or braided. The leading edge of the 8-inch 
(20.3-cm) mesh panel must be 36 meshes wide. The 8-inch (20.3-cm) mesh 
panel must be tapered on each side with all-bar cuts to converge on an 
apex, such that the length of each side is 36 bars. The leading edges of 
the 4-inch (10.2-cm) mesh panels must be 8 meshes wide. The edges of the 
4-inch (10.2-cm) mesh panels must be cut with all-bar cuts running 
parallel to each other, such that the length of the inner edge is 72 
bars and the length of the outer edge is 89 bars and the resulting fore-
and-aft edge is 8 meshes deep. The two 4-inch (10.2-cm) mesh panels must 
be sewn to the 8-inch (20.3-cm) mesh panel to create a single triangular 
excluder panel. The 72-bar edge of each 4-inch (10.2-cm) mesh panel must 
be securely joined with twine to one of the 36-bar edges of the 8-inch 
(20.3-cm) mesh panel, tied with knots at each knot of the 4-inch (10.2-
cm) webbing and at least two wraps of twine around each bar of 4-inch 
(10.2-cm) mesh and the adjoining bar of the 8-inch (20.3-cm) mesh. The 
adjoining fore-and-aft edges of the two 4-inch (10.2-cm) mesh panels 
must be sewn together evenly.
    (ii) Limitations on which trawls may have a Parker TED installed. 
The Parker TED must not be installed or used in a two-seam trawl with a 
tongue, nor in a triple-wing trawl (a trawl with a tongue along the 
headrope and a second tongue along the footrope). The Parker TED may be 
installed and used in any other trawl if the taper of the body panels of 
the trawl does not exceed 4b1p and if it can be properly installed in 
compliance with paragraph (c)(1)(iii) of this section.
    (iii) Panel installation--(A) Leading edge attachment. The leading 
edge of the excluder panel must be attached to the inside of the bottom 
of the trawl across a straight row of meshes. For a two-seam trawl or a 
four-seam, tapered-wing trawl, the row of meshes for attachment to the 
trawl must run the entire width of the bottom body panel, from seam to 
seam. For a four-seam, straight-wing trawl, the row of meshes for 
attachment to the trawl must run the entire width of the bottom body 
panel and half the height of each wing panel of the trawl. Every mesh of 
the leading edge of the excluder panel must be evenly sewn to this row 
of meshes; meshes may not be laced to the trawl. The row of meshes for 
attachment to the trawl must contain the following number of meshes, 
depending on the stretched mesh size used in the trawl:
    (1) For a mesh size of 2\1/4\ inches (5.7 cm), 152-168 meshes;

[[Page 175]]

    (2) For a mesh size of 2\1/8\ inches (5.4 cm), 161-178 meshes;
    (3) For a mesh size of 2 inches (5.1 cm), 171-189 meshes;
    (4) For a mesh size of 1\7/8\ inches (4.8 cm), 182-202 meshes;
    (5) For a mesh size of 1\3/4\ inches (4.4 cm), 196-216 meshes;
    (6) For a mesh size of 1\5/8\ inches (4.1 cm), 211-233 meshes;
    (7) For a mesh size of 1\1/2\ inches (3.8 cm), 228-252 meshes;
    (8) For a mesh size of 1\3/8\ inches (3.5 cm), 249-275 meshes; and
    (9) For a mesh size of 1\1/4\ inches (3.2 cm), 274-302 meshes.
    (B) Apex attachment. The apex of the triangular excluder panel must 
be attached to the inside of the top body panel of the trawl at the 
centerline of the trawl. The distance, measured aft along the centerline 
of the top body panel from the same row of meshes for attachment of the 
excluder panel to the bottom body panel of the trawl, to the apex 
attachment point must contain the following number of meshes, depending 
on the stretched mesh size used in the trawl:
    (1) For a mesh size of 2\1/4\ inches (5.7 cm), 78-83 meshes;
    (2) For a mesh size of 2\1/8\ inches (5.4 cm), 83-88 meshes;
    (3) For a mesh size of 2 inches (5.1 cm), 87-93 meshes;
    (4) For a mesh size of 1\7/8\ inches (4.8 cm), 93-99 meshes;
    (5) For a mesh size of 1\3/4\ inches (4.4 cm), 100-106 meshes;
    (6) For a mesh size of 1\5/8\ inches (4.1 cm), 107-114 meshes;
    (7) For a mesh size of 1\1/2\ inches (3.8 cm), 114-124 meshes;
    (8) For a mesh size of 1\3/8\ inches (3.5 cm), 127-135 meshes; and
    (9) For a mesh size of 1\1/4\ inches (3.2 cm), 137-146 meshes.
    (C) Side attachment. The sides of the excluder panel must be 
attached evenly to the inside of the trawl from the outside attachment 
points of the excluder panel's leading edge to the apex of the excluder 
panel. Each side must be sewn with the same sewing sequence, and, if the 
sides of the excluder panel cross rows of bars in the trawl, the 
crossings must be distributed evenly over the length of the side 
attachment.
    (iv) Escape opening. The escape opening for the Parker soft TED must 
match one of the following specifications:
    (A) Inshore opening. This opening is the minimum size opening that 
may be used in inshore waters, except it may not be used in the inshore 
waters of Georgia and South Carolina, in which a larger minimum opening 
is required. A slit at least 56 inches (1.4 m) in taut length must be 
cut along the centerline of the top body panel of the trawl net 
immediately forward of the apex of the panel webbing. The slit must not 
be covered or closed in any manner. The edges and end points of the slit 
must not be reinforced in any way; for example, by attaching additional 
rope or webbing or by changing the orientation of the webbing.
    (B) Offshore opening. A horizontal cut extending from the attachment 
of one side of the deflector panel to the trawl to the attachment of the 
other side of the deflector panel to the trawl must be made in a single 
row of meshes across the top of the trawl and measure at least 96 inches 
(244 cm) in taut width. All trawl webbing above the deflector panel 
between the 96-inch (244-cm) cut and edges of the deflector panel must 
be removed. A rectangular flap of nylon webbing not larger than 2-inch 
(5.1-cm) stretched mesh may be sewn to the forward edge of the escape 
opening. The width of the flap must not be larger than the width of the 
forward edge of the escape opening. The flap must not extend more than 
12 inches (30.4 cm) beyond the rear point of the escape opening. The 
sides of the flap may be attached to the top of the trawl but must not 
be attached farther aft than the row of meshes through the rear point of 
the escape opening. One row of steel chain not larger than \3/16\ inch 
(4.76 mm) may be sewn evenly to the back edge of the flap. The stretched 
length of the chain must not exceed 96 inches (244 cm). A Parker TED 
using the escape opening described in this paragraph meets the 
requirements of Sec. 223.206(d)(2)(iv)(B). This opening or one that is 
larger must be used in all offshore waters and in the inshore waters of 
Georgia and South Carolina. It also may be used in other inshore waters.

[[Page 176]]

    (2) [Reserved]
    (d) Allowable modifications to hard TEDs and special hard TEDs. 
Unless otherwise prohibited in paragraph (b) of this section, only the 
following modifications may be made to an approved hard TED or an 
approved special hard TED:
    (1) Floats. In addition to floats required pursuant to paragraph 
(a)(9) of this section, floats may be attached to the top one-half of 
the TED, either outside or inside the net, but not to a flap. Floats 
attached inside the net must be behind the rear surface at the top of 
the TED.
    (2) Accelerator funnel. An accelerator funnel may be installed in 
the trawl, if it is made of net webbing material with a stretched mesh 
size of not greater than 1 5/8 inches (4 cm), if it is inserted in the 
net immediately forward of the TED, and if its rear edge does not extend 
past the bars of the TED. The trailing edge of the accelerator funnel 
may be attached to the TED on the side opposite the escape opening if 
not more than one-third of the circumference of the funnel is attached, 
and if the inside horizontal opening as described above in maintained. 
In a bottom opening TED only the top one-third of the circumference of 
the funnel may be attached to the TED. In a top opening TED only the 
bottom one-third of the circumference of the funnel may be attached to 
the TED.
    (i) In inshore waters, other than the inshore waters of Georgia and 
South Carolina in which a larger opening is required, the inside 
horizontal opening of the accelerator funnel must be at least 44 inches 
(112 cm).
    (ii) In offshore waters and the inshore waters of Georgia and South 
Carolina, the inside horizontal opening of the accelerator funnel must 
be at least 71 inches (180 cm).
    (3) Webbing flap. A webbing flap may be used to cover the escape 
opening under the following conditions: No device holds it closed or 
otherwise restricts the opening; it is constructed of webbing with a 
stretched mesh size no larger than 1-5/8 inches (4 cm); it lies on the 
outside of the trawl; it is attached along its entire forward edge 
forward of the escape opening; it is not attached on the sides beyond 
the row of meshes that lies 6 inches (15 cm) behind the posterior edge 
of the grid; the sides of the flap are sewn on the same row of meshes 
fore and aft; and the flap does not overlap the escape hole cut by more 
than 5 inches (13 cm) on either side.
    (i) 44-inch inshore TED flap. This flap may not extend more than 24 
inches (61 cm) beyond the posterior edge of the grid.
    (ii) 71-inch offshore TED Flap. The flap must be a 133-inch (338-cm) 
by 52-inch (132-cm) piece of webbing. The 133-inch (338-cm) edge of the 
flap is attached to the forward edge of the opening (71-inch (180-cm) 
edge). The flap may extend no more than 24 inches (61 cm) behind the 
posterior edge of the grid (Figure 12 to this part illustrates this 
flap).
    (iii) Double cover flap offshore TED flap. This flap must be 
composed of two equal size rectangular panels of webbing. Each panel 
must be no less than 58 inches (147 cm) wide and may overlap each other 
no more than 15 inches (38 cm). The panels may only be sewn together 
along the leading edge of the cut. The trailing edge of each panel must 
not extend more than 6 inches (15 cm) past the posterior edge of the 
grid (Figure 16 to this part). Chafing webbing described in paragraph 
(d)(4) of this section may not be used with this type of flap.
    (4) Chafing webbing. A single piece of nylon webbing, with a twine 
size no smaller than size 36 (2.46 mm in diameter), may be attached 
outside of the escape opening webbing flap to prevent chafing on bottom 
opening TEDs. This webbing may be attached along its leading edge only. 
This webbing may not extend beyond the trailing edge or sides of the 
existing escape opening webbing flap, and it must not interfere or 
otherwise restrict the turtle escape opening.
    (5) Roller gear. Roller gear may be attached to the bottom of a TED 
to prevent chafing on the bottom of the TED and the trawl net. When a 
webbing flap is used in conjunction with roller gear, the webbing flap 
must be of a length such that no part of the webbing flap can touch or 
come in contact with any part of the roller gear assembly or the means 
of attachment of the roller gear

[[Page 177]]

assembly to the TED, when the trawl net is in its normal, horizontal 
position. Roller gear must be constructed according to one of the 
following design criteria:
    (i) A single roller consisting of hard plastic shall be mounted on 
an axle rod, so that the roller can roll freely about the axle. The 
maximum diameter of the roller shall be 6 inches (15.24 cm), and the 
maximum width of the axle rod shall be 12 inches (30.4 cm). The axle rod 
must be attached to the TED by two support rods. The maximum clearance 
between the roller and the TED shall not exceed 1 inch (2.5 cm) at the 
center of the roller. The support rods and axle rod must be made from 
solid steel or solid aluminum rod no larger than \1/2\ inch (1.28 cm) in 
diameter. The attachment of the support rods to the TED shall be such 
that there are no protrusions (lips, sharp edges, burrs, etc.) on the 
front face of the grid. The axle rod and support rods must lie entirely 
behind the plane of the face of the TED grid.
    (ii) A single roller consisting of hard plastic tubing shall be 
tightly tied to the back face of the TED grid with rope or heavy twine 
passed through the center of the roller tubing. The roller shall lie 
flush against the TED. The maximum outside diameter of the roller shall 
be 3\1/2\ inches (8.0 cm), the minimum outside diameter of the roller 
shall be 2 inches (5.1 cm), and the maximum length of the roller shall 
be 12 inches (30.4 cm). The roller must lie entirely behind the plane of 
the face of the grid.
    (6) Water deflector fin for hooped hard TEDs. On a hooped hard TED, 
a water deflector fin may be welded to the forward edge of the escape 
opening. The fin must be constructed of a flat aluminum bar, up to 3/8 
inch (0.95 cm) thick and up to 4 inches (10.2 cm) deep. The fin may be 
as wide as the width of the escape opening, minus 1 inch (2.5 cm). The 
fin must project aft into the TED with an angle between 5[deg] and 
45[deg] from the normal, horizontal plane of the trawl. On an inshore 
hooped hard TED, the clearance between the deflector bars and the 
posterior edge of the deflector fin must be at least 20 inches (51 cm). 
On an offshore hooped hard TED, the clearance between the deflector bars 
and the posterior edge of the deflector fin must be at least 23-1/4 
inches (59 cm).
    (7) Hinged door frame for hooped hard TEDs. A hinged door frame may 
be attached to the forward edge of the escape opening on a hooped hard 
TED. The door frame must be constructed of materials specified at 
paragraphs (a)(1)(i) or (a)(1)(ii) of this section for inshore and 
offshore hooped hard TEDs, respectively. The door frame may be covered 
with a single panel of mesh webbing that is taut and securely attached 
with twine to the perimeter of the door frame, with a mesh size not 
greater than that used for the TED extension webbing. The door frame 
must be at least as wide as the TED escape opening. The door frame may 
be a maximum of 24 inches (61 cm) long. The door frame must be connected 
to the forward edge of the escape opening by a hinge device that allows 
the door to open outwards freely. The posterior edge of the door frame, 
in the closed position, must lie at least 12 inches (30 cm) forward of 
the posterior edge of the escape opening. A water deflector fin may be 
welded to the posterior edge of the hinged door frame. The fin must be 
constructed of a flat aluminum bar, up to 3/8 inch (0.95 cm) thick and 
up to four inches (10.2 cm) deep. The fin may be as wide as the width of 
the escape opening, minus one inch (2.5 cm). The fin must project aft 
into the TED with an angle between 5[deg] and 45[deg] from the normal, 
horizontal plane of the trawl, when the door is in the closed position. 
The clearance between the posterior edge of the escape opening and the 
posterior edge of the door frame or the posterior edge of the water 
deflector fin, if installed, must be no less than 12 inches (30 cm), 
when the door is in the closed position. Two stopper ropes or a hinge 
limiter may be used to limit the maximum opening height of the hinged 
door frame, as long as they do not obstruct the escape opening in any 
way or restrict the free movement of the door to its fully open 
position. When the door is in its fully open position, the minimum 
clearance between any part of the deflector bars and any part of the 
door, including a water deflector fin if installed, must be at least 20 
inches (51 cm) for an inshore hooped

[[Page 178]]

hard TED and at least 23 1/4 inches (59 cm) for an offshore hooped hard 
TED. The hinged door frame may not be used in combination with a webbing 
flap specified at paragraph (d)(3) of this section or with a water 
deflection fin specified at paragraph (d)(6) of this section.
    (e) Revision of generic design criteria, and approval of TEDs, of 
allowable modifications of hard TEDs, and of special hard TEDs. (1) The 
Assistant Administrator may revise the generic design criteria for hard 
TEDs set forth in paragraph (a) of this section, may approve special 
hard TEDs in addition to those listed in paragraph (b) of this section, 
may approve allowable modifications to hard TEDs in addition to those 
authorized in paragraph (d) of this section, or may approve other TEDs, 
by regulatory amendment, if, according to a NMFS-approved scientific 
protocol, the TED demonstrates a sea turtle exclusion rate of 97 percent 
or greater (or an equivalent exclusion rate). Two such protocols have 
been published by NMFS (52 FR 24262, June 29, 1987; and 55 FR 41092, 
October 9, 1990) and will be used only for testing relating to hard TED 
designs. Testing under any protocol must be conducted under the 
supervision of the Assistant Administrator, and shall be subject to all 
such conditions and restrictions as the Assistant Administrator deems 
appropriate. Any person wishing to participate in such testing should 
contact the Director, Southeast Fisheries Science Center, NMFS, 75 
Virginia Beach Dr., Miami, FL 33149-1003.
    (2) Upon application, the Assistant Administrator may issue permits, 
subject to such conditions and restrictions as the Assistant 
Administrator deems appropriate, authorizing public or private 
experimentation aimed at improving shrimp retention efficiency of 
existing approved TEDs and at developing additional TEDs, or conducting 
fishery research, that would otherwise be subject to Sec. 223.206(d)(2). 
Applications should be made to the Southeast Regional Administrator (see 
Sec. 222.102 definition of ``Southeast Regional Administrator'').

[64 FR 14073, Mar. 23, 1999, as amended at 64 FR 55438, Oct. 13, 1999; 
66 FR 1603, Jan. 9, 2001; 66 FR 24288, May 14, 2001; 68 FR 8467, Feb. 
21, 2003; 68 FR 51514, Aug. 27, 2003; 68 FR 54934, Sept. 19, 2003]

    Effective Date Note: At 64 FR 14073, Mar. 23, 1999, Sec. 223.207 was 
added. Paragraphs (a)(9)(ii) (A) and (B) contain information collection 
requirements and will not become effective until approved by the Office 
of Management and Budget.