[Code of Federal Regulations] [Title 46, Volume 7] [Revised as of October 1, 2004] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR182.425] [Page 272-273] TITLE 46--SHIPPING CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PART 182_MACHINERY INSTALLATION--Table of Contents Subpart D_Specific Machinery Requirements Sec. 182.425 Engine exhaust cooling. (a) Except as otherwise provided in this paragraph, all engine exhaust pipes must be water cooled. (1) Vertical dry exhaust pipes are permissible if installed in compliance with Sec. Sec. 177.405(b) and 177.970 of this chapter. (2) Horizontal dry exhaust pipes are permitted only if: (i) They do not pass through living or berthing spaces; (ii) They terminate above the deepest load waterline; (iii) They are so arranged as to prevent entry of cold water from rough or boarding seas; (iv) They are constructed of corrosion resisting material at the hull penetration; and (v) They are installed in compliance with Sec. Sec. 177.405(b) and 177.970 of this chapter. [[Page 273]] (b) The exhaust pipe cooling water system must comply with the requirements of this paragraph. (1) Water for cooling the exhaust pipe must be obtained from the engine cooling water system or a separate engine driven pump. (2) Water for cooling the exhaust pipe, other than a vertical exhaust, must be injected into the exhaust system as near to the engine manifold as practicable. The water must pass through the entire length of the exhaust pipe. (3) The part of the exhaust system between the point of cooling water injection and the engine manifold must be water-jacketed or effectively insulated and protected in compliance with Sec. Sec. 177.405(b) and 177.970 of this chapter. (4) Vertical exhaust pipes must be water-jacketed or suitably insulated as required by Sec. 182.430(g). (5) When the exhaust cooling water system is separate from the engine cooling water system, a suitable warning device, visual or audible, must be installed at the operating station to indicate any reduction in normal water flow in the exhaust cooling system. (6) A suitable hull strainer must be installed in the circulating raw water intake line for the exhaust cooling system. (c) Engine exhaust cooling system built in accordance with the requirements of ABYC Project P-1, ``Installation of Exhaust Systems for Propulsion and Auxiliary Machinery,'' will be considered as meeting the requirements of this section. [CGD 85-080, 61 FR 986, Jan. 10, 1996; 61 FR 20557, May 7, 1996]