Sec. 183.322  Multiple generators.

    When a vessel is equipped with two or more generators to supply 
ship's service power, the following requirements must be met:
    (a) Each generator must have an independent prime mover; and
    (b) The generator circuit breakers must be interlocked to prevent 
the generators from being simultaneously connected to the switchboard, 
except for the circuit breakers of a generator operated in parallel with 
another generator when the installation meets Sec. Sec. 111.12-11(f) 
and 111.30-25(d) in subchapter J of this chapter.