Sec. 183.370  General grounding requirements.

    (a) A vessel's hull must not carry current as a conductor except for 
the following systems:
    (1) Impressed current cathodic protection systems; or
    (2) Battery systems for engine starting.
    (b) Receptacle outlets and attachment plugs for portable lamps, 
tools, and similar apparatus operating at 100 volts or more, must have a 
grounding pole and a grounding conductor in the portable cord.
    (c) Each nonmetallic mast and top mast must have a lightning ground 
conductor.