[Code of Federal Regulations] [Title 46, Volume 1] [Revised as of Octobery 1, 2004] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR28.160] [Page 334-335] TITLE 46--SHIPPING CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PART 28_REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS --Table of Contents Subpart B_Requirements for All Vessels Sec. 28.160 Portable fire extinguishers. (a) Each vessel must meet the requirements of part 25, subpart 25.30 of this chapter. (b) Each vessel 65 feet (19.8 meters) or more in length must be equipped with the minimum number, location, and type of portable fire extinguishers specified in table 28.160. Table 28.160--Portable Fire Extinguishers for Vessels 65 Feet (19.8 Meters) or More in Length ------------------------------------------------------------------------ Space Classification Quantity and location ------------------------------------------------------------------------ Safety areas, communicating A-II............. 1 in each main corridors. corridor not more than 150 feet (49.2 meters) apart. (May be located in stairways.) Pilothouse.................... C-I.............. 2 in vicinity of exit. [[Page 335]] Service spaces, galleys....... B-II or C-II..... 1 for each 2,500 square feet (269.1 sq. meters) or fraction thereof suitable for hazards involved. Paint lockers................. B-II............. 1 outside space in vicinity of exit. Accessible baggage and A-II............. 1 for each 2,500 storerooms. square feet (269.1 sq. meters) or fraction thereof located in the vicinity of exits, either inside or outside the spaces. Work shops and similar spaces. A-II............. 1 outside the space in vicinity of exit. Machinery spaces; Internal B-II............. 1 for each 1,000 combustion propelling brake horsepower or machinery. fraction thereof but not less than 2 nor more than 6. Electric propulsion motors or C-II............. 1 for each propulsion generator unit of open type. motor generator unit. Auxiliary spaces.............. B-II............. 1 outside the space in the vicinity of exit. Internal combustion machinery. B-II............. 1 outside the space in the vicinity of exit. Electric emergency motors or C-II............. 1 outside the space generators. in the vicinity of exit. ------------------------------------------------------------------------ [CGD 88-079, 56 FR 40393, Aug. 14, 1991; 56 FR 47679, Sept. 20, 1991]