[Code of Federal Regulations] [Title 46, Volume 2] [Revised as of October 1, 2004] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR45.113] [Page 82] TITLE 46--SHIPPING CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PART 45_GREAT LAKES LOAD LINES--Table of Contents Subpart D_Conditions of Assignment Sec. 45.113 Access openings in bulkheads at ends of enclosed superstructures. (a) Access openings in bulkheads at ends of enclosed superstructures must have doors of steel or material as strong as steel that are permanently attached to the bulkhead and framed, stiffened, and fitted so that the bulkhead and door are as strong as the bulkhead and weather tight when closed. (b) The means for securing the doors weathertight must be permanently attached to the doors or bulkheads and arranged so that the doors can be secured weathertight from both sides of the bulkhead. (c) Access openings in bulkheads at ends of enclosed superstructures must have sills that are at least 12 inches above the deck.