[Code of Federal Regulations] [Title 46, Volume 2] [Revised as of October 1, 2004] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR45.65] [Page 80] TITLE 46--SHIPPING CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PART 45_GREAT LAKES LOAD LINES--Table of Contents Subpart C_Freeboards Sec. 45.65 Excess sheer limitations. The decrease in freeboard allowed in Sec. 45.63 is limited as follows: Sheer Calculation--Table 4 ---------------------------------------------------------------------------------------------------------------- Station Actual ordinate S. M. Product ---------------------------------------------------------------------------------------------------------------- After Half: AP.................................... ........................... 1 ................................ L/6-AP................................ ........................... 3 ................................ L/3-AP................................ ........................... 3 ................................ Midship............................... ........................... 1 -------------- Sum of Aft Products After Standard Sheer .2665L+26.65\1\.. ........................... ....... -------------- Difference: Sum-STD................... ........................... ....... -------------- +Excess/- Deficiency AFT Sheer: Diff/8..................... ........................... ....... -------------- Excess/Deficiency Fwd. Half: FP.................................... ........................... 1 ................................ L/6-FP................................ ........................... 3 ................................ L/3-FP................................ ........................... 3 ................................ Midships.............................. ........................... 1 -------------- Sum of Fwd Products Fwd Standard Sheer .5330L+53.30\1\... ........................... ....... -------------- Difference: Sum-STD................... ........................... ....... -------------- +Excess/- Deficiency FWD Sheer: Diff/8..................... ........................... ....... -------------- Excess/Deficiency ---------------------------------------------------------------------------------------------------------------- \1\ L in Standard Sheer=L or 500 whichever is less. Sheer Summation Aft Sheer -------------- Fwd Sheer -------------- Net Sheer -------------- Mean: Net-2 -------------- Excess/ Deficiency (a) In vessels having no enclosed superstructure from 0.1 L abaft amidships to 0.1 L forward of amidships, no decrease is allowed. (b) In vessels having enclosed superstructures amidships less than 0.1 L before and abaft amidships, the decrease must be reduced by linear interpolation. (c) If excess sheer exists in the forward half, and the after half is at least 75 percent of standard sheer, the full decrease is allowed. If the after sheer is between 50 percent and 75 percent of standard sheer an intermediate decrease, determined by linear interpolation, is allowed for the excess sheer forward. If the after sheer is 50 percent of standard or less, no decrease is allowed for the excess sheer forward. (d) Where an enclosed poop or forecastle is of standard height with greater sheer than that of the freeboard deck, or is greater than standard height, an addition to the sheer of the freeboard deck may be made using the following formula: S=vL'/3L Where s=sheer credit, to be deducted from the deficiency or added to the excess of sheer. v=difference between actual and standard height of superstructure at the end ordinate. L'=mean enclosed length of poop or forecastle up to a maximum length of 0.5 L. The superstructure deck must not be less than standard height above this curve at any point. This curve must be used in determining the sheer profile for forward and after halves of the vessel. (e) The maximum decreased for excess sheer must be no more than 1\1/ 2\ inches per 100 feet of length. (f) Where the deck of an enclosed superstructure has at least the same sheer as the exposed freeboard deck, the sheer of the enclosed portion of the freeboard deck cannot be taken into account. [[Page 81]]