[Code of Federal Regulations]
[Title 46, Volume 2]
[Revised as of October 1, 2004]
From the U.S. Government Printing Office via GPO Access
[CITE: 46CFR52.01-5]

[Page 125-126]
 
                           TITLE 46--SHIPPING
 
   CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED)
 
PART 52_POWER BOILERS--Table of Contents
 
                   Subpart 52.01_General Requirements
 
Sec. 52.01-5  Plans.

    (a) Manufacturers intending to fabricate boilers to be installed on 
vessels shall submit detailed plans as required by subpart 50.20 of this 
subchapter. The plans, including design calculations, must be certified 
by a registered professional engineer as meeting the design requirements 
in this part and in section I of the ASME Code.
    (b) The following information must be included:
    (1) Calculations for all pressure containment components including 
the maximum allowable working pressure and temperature, the hydrostatic 
or pneumatic test pressure, the maximum steam generating capacity and 
the intended safety valve settings.

[[Page 126]]

    (2) Joint design and methods of attachment of all pressure 
containment components.
    (3) A bill of material meeting the requirements of section I of the 
ASME Code, as modified by this subpart.
    (4) A diagrammatic arrangement drawing of the assembled unit 
indicating the location of internal and external components including 
any interconnecting piping.

(Approved by the Office of Management and Budget under control number 
2115-0142)

[CGD 81-79, 50 FR 9432, Mar. 8, 1985]