[Code of Federal Regulations] [Title 46, Volume 2] [Revised as of October 1, 2004] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR52.25-15] [Page 135] TITLE 46--SHIPPING CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PART 52_POWER BOILERS--Table of Contents Subpart 52.25_Other Boiler Types Sec. 52.25-15 Fired thermal fluid heaters. (a) Fired thermal fluid heaters shall be designed, constructed, inspected, tested, and stamped in accordance with the applicable provisions in this part. (b) Each fired thermal fluid heater must be fitted with a control which prevents the heat transfer fluid from being heated above its flash point. (c) The heat transfer fluid must be chemically compatible with any cargo carried in the cargo tanks serviced by the heat transfer system. (d) Each fired thermal fluid heater must be tested and inspected in accordance with the requirements of subpart 61.30 of this chapter. [CGFR 68-82, 33 FR 18815, Dec. 18, 1968, as amended by CGD 88-057, 55 FR 24236, June 15, 1990]