[Code of Federal Regulations] [Title 46, Volume 2] [Revised as of October 1, 2004] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR56.50-35] [Page 198] TITLE 46--SHIPPING CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PART 56_PIPING SYSTEMS AND APPURTENANCES--Table of Contents Subpart 56.50_Design Requirements Pertaining to Specific Systems Sec. 56.50-35 Condensate pumps. Two means shall be provided for discharging the condensate from the main condenser, one of which shall be mechanically independent of the main propelling machinery. If one of the independent feed pumps is fitted with a direct suction from the condenser and a discharge to the feed tank, it may be accepted as an independent condensate pump. On vessels operating on lakes (including Great Lakes), bays, sounds, or rivers, where provision is made to operate noncondensing, only one condensate unit will be required.