[Code of Federal Regulations] [Title 46, Volume 2] [Revised as of October 1, 2004] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR56.50-45] [Page 198] TITLE 46--SHIPPING CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PART 56_PIPING SYSTEMS AND APPURTENANCES--Table of Contents Subpart 56.50_Design Requirements Pertaining to Specific Systems Sec. 56.50-45 Circulating pumps. (a) A main circulating pump and emergency means for circulating water through the main condenser shall be provided. The emergency means may consist of a connection from an independent power pump fitted between the main circulating pump and the condenser. (b) Independent sea suctions shall be provided for the main circulating and the emergency circulating pumps. (c) A cross connection between the circulating pumps in the case of multiple units will be acceptable in lieu of an independent power pump connection. (d) On vessels operating on lakes (including Great Lakes), bays, sounds, or rivers, where provision is made to operate noncondensing, only one circulating unit will be required.