Sec. 58.01-25  Means of stopping machinery.

    Machinery driving forced-draft and induced-draft fans, fuel-oil 
transfer pumps, fuel-oil unit and service pumps, and similar fuel-oil 
pumps must be fitted with remote controls from a readily accessible 
position outside the space concerned so that the fans or pumps may be 
stopped in case of fire in the compartment in which they are located. 
The controls must be suitably protected against accidental operation and 
against tampering and must be suitably marked.