Sec. 59.15-5  Stayed furnaces and combustion chambers.

    (a) Where the plate forming the walls of stayed furnaces or 
combustion chambers become bulged between staybolts, repairs may be made 
by inserting an additional staybolt in the center of such space 
supported by the four staybolts.
    (b) Where it is desired to rivet a patch to the wall of a stayed 
furnace or combustion chamber, the defective portion of the plate shall 
be cut away until solid material is reached, the patch shall be riveted 
on the waterside, and the staybolts renewed, and extended through the 
new plate.