Sec. 195.134  CPM leak detection.

    This section applies to each hazardous liquid pipeline transporting 
liquid in single phase (without gas in the liquid). On such systems, 
each new computational pipeline monitoring (CPM) leak detection system 
and each replaced component of an existing CPM system must comply with 
section 4.2 of API 1130 in its design and with any other design criteria 
addressed in API 1130 for components of the CPM leak detection system.

[Amdt. 195-62, 63 FR 36376, July 6, 1998]