Sec. 230.48  Number and capacity.

    (a) Number and capacity. Every boiler shall be equipped with at 
least two safety relief valves, suitable for the

[[Page 385]]

service intended, that are capable of preventing an accumulation of 
pressure greater than 6 percent above the MAWP under any conditions of 
service. An FRA inspector may require verification of sufficient safety 
valve relieving capacity.
    (b) Determination of capacity. Safety relief valve capacity may be 
determined by making an accumulation test with the fire in good, bright 
condition and all steam outlets closed. Additional safety relief valve 
capacity shall be provided if the safety relief valves allow an excess 