Sec. 234.243  Wire on pole line and aerial cable.

    Wire on a pole line shall be securely attached to an insulator that 
is properly fastened to a cross arm or bracket supported by a pole or 
other support. Wire shall not interfere with, or be interfered with by, 
other wires on the pole line. Aerial cable shall be supported by 
messenger wire. An open-wire transmission line operating at voltage of 
750 volts or more shall be placed not less than 4 feet above the nearest 
cross arm carrying active warning system circuits.