Sec. 236.109  Time releases, timing relays and timing devices.

    Time releases, timing relays and timing devices shall be tested at 
least once every twelve months. The timing shall be maintained at not 
less than 90 percent of the predetermined time interval, which shall be 
shown on the plans or marked on the time release, timing relay, or 
timing device.