Sec. 236.13  Spring switch; selection of signal control circuits through 
circuit controller.

    The control circuits of signals governing facing movements over a 
main track spring switch shall be selected through the contacts of a 
switch circuit controller, or through the contacts of relay repeating 
the position of such circuit controller, which, when normally closed 
switch point is open one-fourth inch or more, will cause such signals to 
display their most restrictive aspects, except that where a separate 
aspect is displayed for facing movements over the switch in the reverse 
position the signal shall display its most restrictive aspect when the 
switch points are open one-fourth inch or more from either the normal or 
reverse position.