[Code of Federal Regulations] [Title 10, Volume 1] [Revised as of January 1, 2005] From the U.S. Government Printing Office via GPO Access [CITE: 10CFR36.55] [Page 619-620] TITLE 10--ENERGY CHAPTER I--NUCLEAR REGULATORY COMMISSION PART 36_LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS --Table of Contents Subpart D_Operation of Irradiators Sec. 36.55 Personnel monitoring. (a) Irradiator operators shall wear a personnel dosimeter that is processed and evaluated by an accredited National Voluntary Laboratory Accreditation Program (NVLAP) processor while operating a panoramic irradiator or while in the area around the pool of an underwater irradiator. The personnel dosimeter processor must be accredited for high energy photons in the normal and accident dose ranges (see 10 CFR 20.1501(c)). Each personnel dosimeter must be assigned to and worn by only one individual. Film badges must be processed at least monthly, and other personnel dosimeters must be processed at least quarterly. (b) Other individuals who enter the radiation room of a panoramic irradiator shall wear a dosimeter, which may be a pocket dosimeter. For groups of visitors, only two people who enter the radiation room are required to wear dosimeters. If pocket [[Page 620]] dosimeters are used to meet the requirements of this paragraph, a check of their response to radiation must be done at least annually. Acceptable dosimeters must read within plus or minus 30 percent of the true radiation dose. [58 FR 7728, Feb. 9, 1993, as amended at 65 FR 63752, Oct. 24, 2000]