[Title 33 CFR 183.430]
[Code of Federal Regulations (annual edition) - July 1, 2005 Edition]
[Title 33 - NAVIGATION AND NAVIGABLE WATERS]
[Chapter I - COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED)]
[Subchapter S - BOATING SAFETY]
[Part 183 - BOATS AND ASSOCIATED EQUIPMENT]
[Subpart I - Electrical Systems]
[Sec. 183.430 - Conductors in circuits of less than 50 volts.]
[From the U.S. Government Printing Office]


33NAVIGATION AND NAVIGABLE WATERS22005-07-012005-07-01falseConductors in circuits of less than 50 volts.183.430Sec. 183.430NAVIGATION AND NAVIGABLE WATERSCOAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED)BOATING SAFETYBOATS AND ASSOCIATED EQUIPMENTElectrical Systems
Sec. 183.430  Conductors in circuits of less than 50 volts.

    (a) Each conductor in a circuit that has a nominal voltage of less 
than 50 volts must:
    (1) Meet the requirements of Sec. 183.435; or
    (2) Meet:
    (i) The insulating material temperature rating requirements of SAE 
Standard J378; and
    (ii) SAE Standard J1127, or SAE Standard 1128.
    (b) This section does not apply to communication systems; electronic 
navigation equipment; resistance conductors that control circuit 
amperage; and pigtails of less than seven inches of exposed length.

[CGD 73-217, 42 FR 5944, Jan. 31, 1977, as amended by CGD 87-009, 53 FR 
36971, Sept. 23, 1988]