Sec. 258.26  Run-on/run-off control systems.

    (a) Owners or operators of all MSWLF units must design, construct, 
and maintain:
    (1) A run-on control system to prevent flow onto the active portion 
of the landfill during the peak discharge from a 25-year storm;
    (2) A run-off control system from the active portion of the landfill 
to collect and control at least the water volume resulting from a 24-
hour, 25-year storm.
    (b) Run-off from the active portion of the landfill unit must be 
handled in accordance with Sec. 258.27(a) of this part.