Sec. 463.24  New source performance standards.



    Any new source subject to this subpart must achieve performance 

standards (i.e., mass of pollutant discharged)



[[Page 551]]



calculated by multiplying the average process water usage flow rate for 

cleaning processes at a new source times the following pollutant 

concentrations:



                                Subpart B

                            [Cleaning water]

------------------------------------------------------------------------

                  Concentration used to calculate NSPS

-------------------------------------------------------------------------

                                                             Maximum for

                                                Maximum for    monthly

        Pollutant or pollutant property          any 1 day   average (mg/

                                                   (mg/l)         l)

------------------------------------------------------------------------

BOD5..........................................           49           22

Oil and Grease................................           71           17

TSS...........................................          117           36

pH............................................        (\1\)        (\1\)

------------------------------------------------------------------------

\1\ Within the range of 6.0 to 9.0 at all times.





The permit authority will obtain the average process water usage flow 