         Subpart B--Electronic Crystals BAT Effluent Limitations

------------------------------------------------------------------------

                                                             Average of

                                                            daily values

       Pollutant or pollutant property         Maximum for     for 30

                                                any 1 day    consecutive

                                                                days

------------------------------------------------------------------------

                                               Milligrams per liter (mg/

                                                          l)

                                             ---------------

TTO \1\.....................................          1.37      (\3\)

Arsenic\2\..................................          2.09          0.83

Fluoride....................................         32.0          17.4

------------------------------------------------------------------------

\1\ Total toxic organics.

\2\ The arsenic limitation only applies to manufacturers of gallium or

  indium arsenide crystals.