Sec. 60.34b  Emission guidelines for municipal waste combustor operating 

practices.



    (a) For approval, a State plan shall include emission limits for 

carbon monoxide at least as protective as the emission limits for carbon 

monoxide listed in table 3 of this subpart. Table 3 provides emission 

limits for the carbon monoxide concentration level for each type of 

designated facility.



         Table 3--Municipal Waste Combustor Operating Guidelines

------------------------------------------------------------------------

                                                   Carbon

                                                  monoxide

                                                 emissions    Averaging

     Municipal waste combustor technology          level      time (hrs)

                                                 (parts per       b

                                                 million by

                                                 volume) a

------------------------------------------------------------------------

Mass burn waterwall...........................          100            4

Mass burn refractory..........................          100            4

Mass burn rotary refractory...................          100           24

Mass burn rotary waterwall....................          250           24

Modular starved air...........................           50            4

Modular excess air............................           50            4



[[Page 98]]





Refuse-derived fuel stoker....................          200           24

Fluidized bed, mixed fuel (wood/refuse-derived          200         c 24

 fuel)........................................

Bubbling fluidized bed combustor..............          100            4

Circulating fluidized bed combustor...........          100            4

Pulverized coal/refuse-derived fuel mixed fuel-         150            4

 fired combustor..............................

Spreader stoker coal/refuse-derived fuel mixes          200          24

 fuel-fired combustor.........................

------------------------------------------------------------------------

a Measured at the combustor outlet in conjunction with a measurement of

  oxygen concentration, corrected to 7 percent oxygen, dry basis.

  Calculated as an arithmetic average.

b Averaging times are 4-hour or 24-hour block averages.

c 24-hour block average, geometric mean.



    (b) For approval, a State plan shall include requirements for 

municipal waste combustor operating practices at least as protective as 

those requirements listed in Sec. 60.53b(b) and (c) of subpart Eb of 

this part.



[60 FR 65415, Dec. 19, 1995, as amended at 62 FR 45120, 45125, Aug. 25, 

1997; 69 FR 42121, July 14, 2004]