[Code of Federal Regulations]

[Title 40, Volume 13]

[Revised as of July 1, 2005]

From the U.S. Government Printing Office via GPO Access

[CITE: 40CFR63.7114]



[Page 45]

 

                   TITLE 40--PROTECTION OF ENVIRONMENT

 

         CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)

 

PART 63_NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR 

SOURCE CATEGORIES--Table of Contents

 

 Subpart AAAAA_National Emission Standards for Hazardous Air Pollutants 

                      for Lime Manufacturing Plants

 

Sec. 63.7114  How do I demonstrate initial compliance with the emission 

limitations standard?



    (a) You must demonstrate initial compliance with each emission limit 

in Table 1 to this subpart that applies to you, according to Table 3 to 

this subpart. For existing lime kilns and their associated coolers, you 

may perform VE measurements in accordance with EPA Method 9 of appendix 

A to part 60 in lieu of installing a COMS or PM detector if any of the 

conditions in paragraphs (a)(1) through (3) of this section exist:

    (1) You use a FF for PM control, and the FF is under positive 

pressure and has multiple stacks; or

    (2) The control device exhausts through a monovent; or

    (3) The installation of a COMS in accordance with PS-1 of appendix B 

to part 60 is infeasible.

    (b) You must establish each site-specific operating limit in Table 2 

to this subpart that applies to you according to the requirements in 

Sec. 63.7112(j) and Table 4 to this subpart. Alternative parameters may 

be monitored if approval is obtained according to the procedures in 

Sec. 63.8(f)

    (c) You must submit the Notification of Compliance Status containing 

the results of the initial compliance demonstration according to the 

requirements in Sec. 63.7130(e).



                   Continuous Compliance Requirements