[Code of Federal Regulations]

[Title 47, Volume 1]

[Revised as of October 1, 2005]

From the U.S. Government Printing Office via GPO Access

[CITE: 47CFR18.305]



[Page 876-877]

 

                       TITLE 47--TELECOMMUNICATION

 

              CHAPTER I--FEDERAL COMMUNICATIONS COMMISSION

 

PART 18_INDUSTRIAL, SCIENTIFIC, AND MEDICAL EQUIPMENT--Table of Contents

 

                      Subpart C_Technical Standards

 

Sec. 18.305  Field strength limits.



    (a) ISM equipment operating on a frequency specified in Sec. 18.301 

is permitted unlimited radiated energy in the band specified for that 

frequency.

    (b) The field strength levels of emissions which lie outside the 

bands specified in Sec. 18.301, unless otherwise indicated, shall not 

exceed the following:



----------------------------------------------------------------------------------------------------------------

                                                           RF Power generated by  Field strength limit  Distance

             Equipment               Operating frequency     equipment (watts)           (uV/m)         (meters)

----------------------------------------------------------------------------------------------------------------

Any type unless otherwise           Any ISM frequency....  Below 500............  25..................       300

 specified (miscellaneous).                                500 or more..........  25xSQRT(power/500)..    \1\300

                                    Any non-ISM frequency  Below 500............  15..................       300

                                                           500 or more..........  15xSQRT(power/500)..    \1\300

Industrial heaters and RF           On or below 5,725 MHz  Any..................  10..................     1,600

 stabilized arc welders.            Above 5,725 MHz......  Any..................  (\2\)...............     (\2\)

Medical diathermy.................  Any ISM frequency....  Any..................  25..................       300

                                    Any non-ISM frequency  Any..................  15..................       300

Ultrasonic........................  Below 490 kHz........  Below 500............  2,400/F(kHz)........       300

                                                           500 or more..........  2,400/F(kHz)x           \3\300

                                                                                   SQRT(power/500).

                                    490 to 1,600 kHz.....  Any..................  24,000/F(kHz).......        30

                                    Above 1,600 kHz......  Any..................  15..................        30

Induction cooking ranges..........  Below 90 kHz.........  Any..................  1,500...............     \4\30

                                    On or above 90 kHz...  Any..................  300.................     \4\30

----------------------------------------------------------------------------------------------------------------

\1\ Field strength may not exceed 10 [mu]V/m at 1600 meters. Consumer equipment operating below 1000 MHz is not

  permitted the increase in field strength otherwise permitted here for power over 500 watts.

\2\ Reduced to the greatest extent possible.

\3\ Field strength may not exceed 10 [mu]V/m at 1600 meters. Consumer equipment is not permitted the increase in

  field strength otherwise permitted here for over 500 watts.

\4\ Induction cooking ranges manufactured prior to February 1, 1980, shall be subject to the field strength

  limits for miscellaneous ISM equipment.



    (c) The field strength limits for RF lighting devices shall be the 

following:



------------------------------------------------------------------------

                                       Field strength limit at 30 meters

           Frequency (MHz)                         ([mu]V/m)

------------------------------------------------------------------------

Non-consumer equipment:

    30-88...........................                  30

    88-216..........................                  50

    216-1000........................                  70

Consumer equipment:

    30-88...........................                  10

    88-216..........................                  15

    216-1000........................                  20

------------------------------------------------------------------------



                                  Notes



    1. The tighter limit shall apply at the boundary between two 

frequency ranges.



[[Page 877]]



    2. Testing for compliance with these limits may be made at closer 

distances, provided a sufficient number of measurements are taken to 

plot the radiation pattern, to determine the major lobes of radiation, 

and to determine the expected field strength level at 30, 300, or 1600 

meters. Alternatively, if measurements are made at only one closer fixed 

distance, then the permissible field strength limits shall be adjusted 

using 1/d as an attenuation factor.



[50 FR 36070, Sept. 5, 1985, as amended at 51 FR 17970, May 16, 1986; 52 

FR 43197, Nov. 10, 1987]