Sec. 18.309  Frequency range of measurements.



    (a) For field strength measurements:



----------------------------------------------------------------------------------------------------------------

                                                             Range of frequency measurements

Frequency band in which device operates ------------------------------------------------------------------------

                 (MHz)                             Lowest frequency                    Highest frequency

----------------------------------------------------------------------------------------------------------------

Below 1.705............................  Lowest frequency generated in the    30 MHz.

                                          device, but not lower than 9 kHz.

1.705 to 30............................  Lowest frequency generated in the    400 MHz.

                                          device, but not lower than 9 kHz.

30 to 500..............................  Lowest frequency generated in the    Tenth harmonic or 1,000 MHz,

                                          device or 25 MHz, whichever is       whichever is higher.

                                          lower.

500 to 1,000...........................  Lowest frequency generated in the    Tenth harmonic.

                                          device or 100 MHz, whichever is

                                          lower.

Above 1,000............................  ......do...........................  Tenth harmonic or highest

                                                                               detectable emission.

----------------------------------------------------------------------------------------------------------------





[[Page 878]]



    (b) For conducted powerline measurements, the frequency range over 

which the limits are specified will be scanned.