Sec. 180.213  Requalification markings.



    (a) General. Each cylinder requalified in accordance with this 

subpart with acceptable results must be marked as specified in this 

section. Required specification markings may not be altered or removed.

    (b) Placement of markings. Each cylinder must be plainly and 

permanently marked on the metal of the cylinder as permitted by the 

applicable specification. Unless authorized by the cylinder 

specification, marking on the cylinder sidewall is prohibited.

    (1) Requalification and required specification markings must be 

legible so as to be readily visible at all times. Illegible 

specification markings may be remarked on the cylinder as provided by 

the original specification. Requalification markings may be placed on 

any portion of the upper end of the cylinder excluding the sidewall, as 

provided in this section. Requalification and required specification 

markings that are illegible may be reproduced on a metal plate and 

attached as provided by the original specification.

    (2) Previous requalification markings may not be obliterated, except 

that, when the space originally provided for requalification dates 

becomes filled, additional dates may be added as follows:

    (i) All preceding requalification dates may be removed by peening 

provided that--

    (A) Permission is obtained from the cylinder owner;

    (B) The minimum wall thickness is maintained in accordance with 

manufacturing specifications for the cylinder; and

    (C) The original manufacturing test date is not removed.

    (ii) When the cylinder is fitted with a footring, additional dates 

may be marked on the external surface of the footring.

    (c) Requalification marking method. The depth of requalification 

markings may not be greater than specified in the applicable 

specification. The markings must be made by stamping, engraving, 

scribing or other method that produces a legible, durable mark.

    (1) A cylinder used as a fire extinguisher (Sec. 180.209(j)) may be 

marked by using a pressure sensitive label.

    (2) For a DOT 3HT cylinder, the test date and RIN must be applied by 

low-stress steel stamps to a depth no greater than that prescribed at 

the time of manufacture. Stamping on the sidewall is not authorized.

    (d) Requalification markings. Each cylinder that has successfully 

passed requalification must be marked with the RIN set in a square 

pattern, between the month and year of the requalification date. The 

first character of the RIN must appear in the upper left corner of the 

square pattern; the second in the upper right; the third in the lower 

right, and the fourth in the lower left. Example: A cylinder requalified 

in September 1998, and approved by a person who has been issued RIN 

``A123'', would be marked plainly and permanently into the metal of the 

cylinder in accordance with location requirements of the cylinder 

specification or on a metal plate permanently secured to the cylinder in 

accordance with paragraph (b) of this section. An example of the 

markings prescribed in this paragraph (d) is as follows:

[GRAPHIC] [TIFF OMITTED] TR08AU02.018



Where:

``9'' is the month of requalification,

``A123'' is the RIN,

``98'' is the year of requalification, and

``X'' represents the symbols described in paragraphs (f)(2) through 

(f)(7) of this section.



    (1) Upon a written request, variation from the marking requirement 

may be approved by the Associate Administrator.

    (2) Exception. A cylinder subject to the requirements of Sec. 

173.301(l) of this subchapter may not be marked with a RIN.

    (e) Size of markings. The size of the markings must be at least 6.35 

mm (\1/4\ in.) high, except RIN characters must be at least 3.18 mm (\1/

8\ in.) high.



[[Page 1098]]



    (f) Marking illustrations. Examples of required requalification 

markings for DOT specification and exemption cylinders are illustrated 

as follows:

    (1) For designation of the 5-year volumetric expansion test, 10-year 

volumetric expansion test for cylinders conforming to Sec. 180.209(f) 

and (h), or 12-year volumetric expansion test for fire extinguishers 

conforming to Sec. 173.309(b) of this subchapter and cylinders 

conforming to Sec. 180.209(e) and Sec. 180.209(g), the marking is as 

illustrated in paragraph (d) of this section.

    (2) For designation of the 10-year volumetric expansion test for 

cylinders conforming to Sec. 180.209(b), the marking is as illustrated 

in paragraph (d) of this section, except that the ``X'' is replaced with 

a five-point star.

    (3) For designation of special filling limits up to 10% in excess of 

the marked service pressure for cylinders conforming to Sec. 

173.302a(b) of this subchapter, the marking is as illustrated in 

paragraph (d) of this section, except that the ``X'' is replaced with a 

plus sign ``+''.

    (4) For designation of the proof pressure test, the marking is as 

illustrated in paragraph (d) of this section, except that the ``X'' is 

replaced with the letter ``S''.

    (5) For designation of the 5-year external visual inspection for 

cylinders conforming to Sec. 180.209(g), the marking is as illustrated 

in paragraph (d) of this section, except that the ``X'' is replaced with 

the letter ``E''.

    (6) For designation of DOT 8 series cylinder shell requalification 

only, the marking is as illustrated in paragraph (d) of this section, 

except that the ``X'' is replaced with the letter ``S''.

    (7) For designation of DOT 8 series cylinder shell and porous filler 

requalification, the marking is as illustrated in paragraph (d) of this 

section, except that the ``X'' is replaced with the letters ``FS''.