Sec. 230.37  Steam test following repairs or alterations.



    Upon completion of any repair or alteration, the locomotive owner 

and/or operator shall conduct a steam test of the boiler with steam 

pressure raised to between 95 percent and 100 percent of the MAWP. At 

this time, the boiler shall be inspected to ensure that it is in a safe 

and suitable condition for service.



                                Staybolts