Sec. 230.51  Number and location.



    Every boiler shall be equipped with at least two water glasses. The 

lowest reading of the water glasses shall not be less than 3 inches 

above the highest part of the crown sheet. If gauge cocks are used, the 

reading of the lowest gauge cock shall not be less than 3 inches above 

the highest part of the crown sheet.