Sec. 236.17  Pipe for operating connections, requirements.



    (a) Steel or wrought-iron pipe one inch or larger, or members of 

equal strength, shall be used for operating connections for switches, 

derails, movable-point frogs, facing-point locks, rail-locking devices 

of movable bridge protected by interlocking, and mechanically operated 

signals, except up-and-down rod which may be three-fourths inch pipe or 

solid rod. Pipe shall be fully screwed into coupling and both ends of 

each pipe shall be riveted to pipe plug with 2 rivets.

    (b) Pipeline shall not be out of alignment sufficiently to interfere 

with proper operation, shall be properly compensated for temperature 

changes, and supported on carriers spaced not more than 8 feet apart on 

tangent and curve of less than 2[deg] and not more than 7 feet apart on 

curve of 2[deg] or more. With lever in any position, couplings in pipe 

line shall not foul carriers.