Sec. 236.6  Hand-operated switch equipped with switch circuit controller.



    Hand-operated switch equipped with switch circuit controller 

connected to the point, or with facing-point lock and circuit 

controller, shall be so maintained that when point is open one-fourth 

inch or more on facing-point switch and three-eights inch or more on 

trailing-point switch, track or control circuits will be opened or 

shunted or both, and if equipped with facing-point lock with circuit 

controller, switch cannot be locked. On such hand-operated switch, 

switch circuit controllers, facing-point locks, switch-and-lock 

movements, and their connections shall be securely fastened in place, 

and contacts maintained with an opening of not less than one-sixteenth 

inch when open.