Sec.  3280.112  Hallways.



    Hallways shall have a minimum horizontal dimension of 28 inches 

measured from the interior finished surface to the interior finished 

surface of the opposite wall. When appliances are installed in a laundry 

area, the measurement shall be from the front of the appliance to the 

opposite finished interior surface. When appliances are not installed 

and a laundry area is provided, the area shall have a minimum clear 

depth of 27 inches in addition to the 28 inches required for passage. In 

addition, a notice of the available clearance for washer/dryer units 

shall be posted in the laundry area. Minor protrusions into the minimum 

hallway width by doorknobs, trim, smoke alarms or light fixtures are 

permitted.



[40 FR 58752, Dec. 18, 1975. Redesignated at 44 FR 20679, Apr. 6, 1979, 

and further redesignated at 58 FR 55004, Oct. 25, 1993; 67 FR 12817, 

Mar. 19, 2002]