Sec. 31.46  Pressurized fuel systems.



    For pressurized fuel systems, each element and its connecting 

fittings and lines must be tested to an ultimate pressure of at least 

twice the maximum pressure to which the system will be subjected in 

normal operation. No part of the system may fail or malfunction during 

the test. The test configuration must be representative of the normal 

fuel system installation and balloon configuration.