Sec.  207.718  Navigation locks and approach channels, Columbia and 

Snake Rivers, Oreg. and Wash.



    (a) General. All locks, approach channels, and all lock 

appurtenances, shall be under the jurisdiction of the District Engineer, 

Corps of Engineers, U.S. Army, in charge of the locality. The district 

engineer may, after issuing a public notice and providing a 30-day 

opportunity for public comment, set (issue) a schedule for the daily 

lockage of recreational vessels. Recreational vessels are pleasure boats 

such a row, sail, or motor boats used for recreational purposes. 

Commercial vessels include licensed commercial passenger vessels 

operating on a published schedule or regularly operating in the ``for 

hire'' trade. Any recreational schedule shall provide for a minimum of 

one scheduled recreation lockage upstream and downstream (two lockages) 

each day. At the discretion of the district engineer, additional 

lockages may be scheduled. Each schedule and any changes to the schedule 

will be issued at least 30 days prior to implementation. Prior to 

issuing any schedule or any change to the schedule, the district 

engineer will consider all public comments and will evaluate the 

expected energy situation, water supply, and recreation use of the lock 

to determine the seasonal need for the schedule or change in schedule. 

The district engineer's representative at the locks shall be the project 

engineer, who shall issue orders and instructions to the lockmaster in 

charge of the lock. Hereinafter, the term ``lockmaster'' shall be used 

to designate the person in immediate charge of the lock at any given 

time. In case of emergency and on all routine work in connection with 

the operation of the lock, the lockmaster shall have authority to take 

action without waiting for instructions from the project engineer.

    (b) Lockage control. The Lock Master shall be charged with immediate 

control and management of the lock, and of the area set aside as the 

lock area, including the lock approach channels. Upstream and downstream 

approach channels extend to the end of the wing or the guide wall, 

whichever is longer. At Bonneville lock the upstream approach channel 

extends to the mooring tie offs at Fort Rains and the downstream 

approach channel extends to the downstream tip of Robins Island. The 

Lock Master shall demand compliance with all laws, rules and regulations 

for the use of the lock and lock area and is authorized to issue 

necessary orders and directions, both to employees of the Government or 

to other persons within the limits of the lock or lock area, whether 

navigating the lock or not. Use of lock facilities is contingent upon 

compliance with regulations, Lock Master instructions and the safety of 

people and property.

    (c) Authority of Lock Master. No one shall initiate any movement of 

any vessel in the lock or approaches except by or under the direction of 

the Lock Master. (``Vessel'' as used herein includes all connected 

units, tugs, barges, tows, boats or other floating objects.)

    (d) Signals--(1) Radio. All locks are equipped with two-way FM radio 

operating on channel 14, frequency of 156.700 MHz, for both the calling 

channel and the working channel. Vessels equipped with two-way radio 

desiring a lockage shall call WUJ 33 Bonneville, WUJ 34 The Dalles, WUJ 

35 John Day, WUJ 41 McNary, WUJ 42 Ice Harbor, WUJ 43 Lower Monumental, 

WUJ 44 Little Goose, or WUJ 45 Lower Granite,



[[Page 95]]



at least one-half hour in advance of arrival since the Lock Master is 

not in constant attendance of the locks. Channel 14 shall be monitored 

constantly in the vessel pilot house from the time the vessel enters the 

approach channel until its completion of exit. Prior to entering the 

lock chamber, the commercial freight or log-tow vessel operator shall 

report the nature of any cargo, the maximum length, width and draft of 

the vessel and whether the vessel is in any way hazardous because of its 

condition or the cargo it carries or has carried.

    (2) Pull-cord signal stations. Pull-cord signal stations marked by 

large instructional signs and located near the end of the upstream and 

downstream lock entrance walls may be used in place of radios to signal 

the Lock Master for a lockage.

    (3) Entering and exit signals. Signal lights are located outside 

each lock gate. When the green (go) light is on, all vessels will enter 

in the sequence prescribed by the Lock Master. When the red (stop) light 

is on, the lock is not ready for entrance and vessels shall stand clear. 

In addition to the above visual signals, the Lock Master will signal 

that the lock is ready for entrance by sounding one long blast on the 

lock air horn. The Lock Master will signal that the lock is ready for 

exit by lighting the green exit light and sounding one short blast on 

the air horn.

    (4) Craft lockage-readiness signal. Upon query from Lock Master, a 

vessel operator will signal when he is properly moored and ready for the 

lockage to begin.

    (e) Permissible dimensions of vessels. Nominal overall dimensions of 

vessels allowed in the lock chamber are 84 feet wide and 650 feet long. 

Depth of water in the lock depends upon river levels which may vary from 

day to day. Staff gauges showing the minimum water level depth over gate 

sills are located inside the lock chamber near each lock gate and 

outside the lock chamber near the end of both upstream and downstream 

guide walls, except at Bonneville where the staff gauges show water 

levels in feet above MSL and are located on the southern guide walls at 

the upstream and downstream miter gates. Bonneville's upstream sill 

elevation is 51 feet MSL and the downstream sill elevation is -12 feet 

MSL. Depth over sill at Bonneville is determined by subtracting the sill 

elevation from the gauge reading. Vessels shall not enter the navigation 

lock unless the vessel draft is at least one foot less than the water 

depth over the sill. Information concerning allowable draft for vessel 

passage through the locks may be obtained from the Lock Master. Minimum 

lock chamber water level depth is 15 feet except at Ice Harbor where it 

is 14 feet and at Bonneville where it is 19 feet. When the river flow at 

Lower Granite exceeds 330,000 cubic feet per second the normal minimum 

15-foot depth may be decreased to as little as eight feet.

    (f) Precedence at lock. Subject to the order of precedence, the 

vessel or tow arriving first; at the lock will be locked through first, 

however, this precedence may be modified at the discretion of the 

lockmaster. If immediate passage is required, lockage of vessels owned 

or operated by the United States shall take precedence. The precedence 

of all other vessels shall be as follows:

    (1) When a recreational vessel lockage schedule is in effect, at the 

appointed time for lockage of recreation craft, recreation craft shall 

take precedence; however, commercial vessels may be locked through with 

recreation craft if safety and space permit. At other than the appointed 

time, the lockage of commercial and tow vessels shall take precedence 

and recreational craft may (only) lock through with commercial vessels 

only as provided in paragraph (h) of this section.

    (2) If a recreational vessel lockage schedule is not in effect, 

commercial and tow vessels shall take precedence. Recreational craft may 

be locked through with commercial craft. If no commercial vessels are 

scheduled to be locked through within a reasonable time, not to exceed 

one hour after the arrival of the recreational vessels at the lock, the 

recreational vessel may be locked through separately. If a combined 

lockage cannot be arranged, the recreational craft shall be locked 

through after waiting three commercial lockages.



[[Page 96]]



    (g) Loss of turn. Vessels that fail to enter the lock with 

reasonable promptness, after being authorized to do so, shall lose their 

turn.

    (h) Lockage--(1) Multiple lockage. The Lock Master shall decide 

whether one or more vessels or tows may be locked through at the same 

time. Vessels with flammable or highly hazardous cargo will be passed 

separately from all other vessels. Hazardous materials are described in 

part 171, title 49, Code of Federal Regulations. Flammable materials are 

defined in the National Fire Code of the National Fire Protection 

Association.

    (2) Recreational craft. By mutual agreement of (all parties,) the 

lockmaster and the captains of the vessels involved, recreational 

vessels may be locked through with commercial vessels. Under the 

recreational vessel schedule, separate lockage will not be made by 

recreational vessels except in accordance with the recreational lockage 

schedule or when circumstances warrant, such as in an emergency. When 

recreational craft are locked simultaneously with commercial vessels, 

the recreational vessel will enter the lock chamber after the commercial 

vessel is secured in the chamber and when practicable will depart while 

the commercial vessel remains secured.

    (3) Special schedules. Recreational boating groups may request 

special schedules by contacting the district engineer. The schedule for 

the daily lockage of recreational vessels will indicate the number of 

boats required for a special schedule and how many days' notice is 

required in order to arrange a special schedule.

    (i) Mooring in approaches prohibited. Mooring or anchoring in the 

approaches to the lock is prohibited where such mooring will interfere 

with navigation.

    (j) Waiting for lockage. Vessels waiting for lockage shall wait in 

the clear outside of the lock approach channel, or contingent upon 

permission by the Lock Master, may at their own risk, lie inside the 

approach channel at a place specified by the Lock Master. At Bonneville, 

vessels may at their own risk, lay-to at the downstream moorage facility 

on the north shore downstream from the north guide wall provided a 100-

foot-wide open channel is maintained.

    (k) Mooring in lock. All vessels must be moored within the lock 

chamber so that no portion of any vessel extends beyond the lines 

painted on the lock walls. Moorage within the lock chamber will be to 

floating mooring bits only and will be accomplished in a proper no-slip 

manner. Small vessels will not be locked with a large vessel unless the 

large vessel is so moored (two mooring bits) that no lateral movement is 

possible. The vessel operator will constantly monitor the position of 

his vessel and his mooring bit ties to assure that there is no fore or 

aft movement of his vessel and lateral movement is minimized. Propulsion 

by vessels within the lock chamber will not be permitted during closure 

operation of a lock chamber gate or as otherwise directed by the Lock 

Master.

    (l) Crew to move craft. During the entire lockage, the vessel 

operator shall constantly attend the wheelhouse, be aware of the 

vessel's position, and monitor radio channel 14 on frequency 156.700 

MHz, or otherwise be constantly able to communicate with the Lock 

Master. At a minimum, vessels shall be as vigilantly manned as if 

underway.

    (m) Speed. Vessels shall be adequately powered to maintain a safe 

speed and be under control at all times. Vessels shall not be raced or 

crowded alongside another in the approach channels. When entering the 

lock, speed shall be reduced to a minimum consistent with safe 

navigation. As a general rule, when a number of vessels are entering the 

lock, the following vessel shall remain at least 200 feet astern of the 

vessel ahead.

    (n) Delay in lock. Vessels shall not unnecessarily delay any 

operation of the locks.

    (o) Landing of freight. No freight, baggage, personnel, or 

passengers shall be landed on or over the walls of the lock, except by 

permission and direction of the Lock Master.

    (p) Damage to lock or other structures. The regulations in this 

section shall not relieve owners and/or operators of vessels from 

liability for any damage to the lock or other structures or for



[[Page 97]]



the immediate removal of any obstruction. No vessel in less than stable 

floating condition or having unusual sinking potential shall enter the 

locks or its approaches. Vessels must use great care not to strike any 

part of the lock, any gate or appurtenance thereto, or machinery for 

operating the gates, or the walls protecting the banks of the approach 

channels. All vessels with projecting irons, or rough surfaces which may 

damage the gates or lock walls, shall not enter the lock unless provided 

with suitable buffers and fenders. Vessels having chains, lines, or 

drags either hanging over the sides or ends or dragging on the bottom 

for steering or other purposes will not be permitted to pass.

    (q) Tows. Prior to a lockage, the person in charge of a vessel 

towing a second vessel by lines shall, at a safe distance outside of the 

incoming approach channel, secure the second vessel to the towing vessel 

and keep it secured during the entire course of a lockage and until 

safely clear of the outgoing approach channel.

    (r) Violation of regulations. Any violation of these regulations may 

subject the owner or master of any vessel to any or all of the 

following: (1) Penalties prescribed by law of the U.S. Government (33 

U.S.C. part 1); (2) Report of violation to the titled owner of the 

vessel; (3) Report of violation to the U.S. Coast Guard; (4) Refusal of 

lockage at the time of violation.

    (s) Refuse in locks. No material of any kind shall be thrown or 

discharged into the lock, or be deposited in the lock area. Vessels 

leaking or spilling cargo will be refused lockage and suitable reports 

will be made to the U.S. Coast Guard. Deck cargo will be so positioned 

so as not to be subject to falling overboard.

    (t) Handling valves, gates, bridges, and machinery. No person, 

unless authorized by the Lock Master, shall open or close any bridge, 

gate, valve, or operate any machinery in connection with the lock. 

However, the Lock Master may call for assistance from the master of any 

vessel using the lock, should such aid be necessary; and when rendering 

such assistance, the person so employed shall be directly under the 

orders of the Lock Master. Masters of vessels refusing to provide such 

assistance when it is requested of them may be denied the use of the 

lock by the Lock Master.

    (u)-(v) [Reserved]

    (w) Restricted areas. No vessel shall enter or remain in any 

restricted area at any time without first obtaining permission from the 

District Engineer, Corps of Engineers, U.S. Army, or his duly authorized 

representative.

    (1) At Bonneville Lock and Dam. The water restricted to all vessels, 

except Government vessels, are described as all waters of the Columbia 

River and Bradford Slough within 1,000 feet above the first powerhouse, 

spillway, and second powerhouse (excluding the new navigation lock 

channel) and all waters below the first powerhouse, spillway, second 

powerhouse, and old navigation lock. This is bounded by a line 

commencing from the westernmost tip of Robins Island on the Oregon side 

of the river and running in a South 65 degrees West direction a distance 

of approximately 2,100 feet to a point 50 feet upstream of the Hamilton 

Island Boat Ramp on the Washington shore. Signs designate the restricted 

areas. The approach channel to the new navigation lock is outside the 

restricted area.

    (2) At the Dalles Dam. The waters restricted to only Government 

vessels are described as all downstream waters other than those of the 

navigation lock downstream approach channel which lie between the Wasco 

County Bridge and the project axis including those waters between the 

powerhouse and the Oregon shore and all upstream waters other than those 

of the navigation lock upstream approach channel which lie between the 

project axis and a line projected from the upstream end of the 

navigation lock guide wall to the junction of the concrete structure 

with the earth fill section of the dam near the upstream end of the 

powerhouse.

    (3) At the John Day Dam. The waters restricted to only Government 

vessels are described as all of the waters within a distance of about 

1,000 yards above the dam lying south of the navigation channel leading 

to the lock and bounded by a line commencing at the upstream end of the 

guide wall, and running in a direction 54[deg]01[min]37[sec] true for a 

distance of 771 yards, thence 144[deg]01[min]37[sec] true across the 

river to the south



[[Page 98]]



shoreline. The downstream limit is marked by orange and white striped 

monuments on the north and south shores.

    (4) At McNary Lock and Dam. The waters restricted to all vessels, 

except to Government vessels, are described as all waters commencing at 

the upstream end of the Oregon fish ladder thence running in the 

direction of 39[deg]28[min] true for a distance of 540 yards; thence 

7[deg]49[min] true for a distance of 1,078 yards; thence 277[deg]10[min] 

for a distance of 468 yards to the upstream end of the navigation lock 

guidewall. The downstream limits commence at the downstream end of the 

navigation lock guidewall thence to the south (Oregon) shore at right 

angles and parallel to the axis of the dam. Signs designate the 

restricted areas.

    (5) At Ice Harbor Lock and Dam. The waters restricted to all 

vessels, except Government vessels, are described as all waters within a 

distance of about 800 yards upstream of the dam lying south of the 

navigation lock and bound by the line commencing at the upstream end of 

the guidewall, and running a direction of 91[deg]10[min] true for a 

distance of 575 yards; thence 162[deg]45[min] to the south shore, a 

distance of about 385 yards. The downstream limits commencing at the 

downstream end of the guidewall; thence to the south shore, at right 

angles and parallel to the axis of the dam. Signs designate the 

restricted areas.

    (6) At Lower Monumental Lock and Dam. The waters restricted to all 

vessels, except Government vessels, are described as all waters 

commencing at the upstream of the navigation lock guidewall and running 

in a direction of 46[deg]25[min] true for a distance of 344 yards; 

thence 326[deg]19[min] true for a distance of 362 yards; thence 

243[deg]19[min] true for a distance of 218 yards; thence 275[deg]59[min] 

true to the north shore a distance of about 290 yards. The downstream 

limits commence at the downstream end of the navigation lock guidewall; 

thence to the north shore, at right angles and parallel to the axis of 

the dam. Signs designate the restricted areas.

    (7) At Little Goose Lock and Dam. The waters restricted to all 

vessels, except Government vessels, are described as all waters 

commencing at the upstream of the navigation lock guidewall and running 

in a direction of 60[deg]37[min] true for a distance of 676 yards; 

thence 345[deg]26[min] true for a distance of 494 yards; thence 

262[deg]37[min]47[sec] true to the dam embankment shoreline. The 

downstream limits commence 512 yards downstream and at right angles to 

the axis of the dam on the south shore; thence parallel to the axis of 

the dam to the north shore. Signs designate the restricted areas.

    (8) At Lower Granite Lock and Dam. The waters restricted to all 

vessels, except Government vessels, are described as all waters 

commencing at the upstream of the navigation lock guidewall thence 

running in the direction of 131[deg]31[min] true for a distance of 608 

yards; thence 210[deg]46[min] true to the south shore, a distance of 

about 259 yards. The downstream limits commence at the downstream end of 

navigation lock guidewall; thence to the south shore, at right angles 

and parallel to the axis of the dam. Signs designate the restricted 

areas.



[43 FR 3115, Jan. 23, 1978, as amended at 52 FR 22310, June 11, 1987; 56 

FR 13765, Apr. 4, 1991; 65 FR 4125, Jan. 26, 2000; 71 FR 25503, May 1, 

2006]