[Code of Federal Regulations]

[Title 40, Volume 28]

[Revised as of July 1, 2006]

From the U.S. Government Printing Office via GPO Access

[CITE: 40CFR411.12]



[Page 192]

 

                   TITLE 40--PROTECTION OF ENVIRONMENT

 

         CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)

 

PART 411_CEMENT MANUFACTURING POINT SOURCE CATEGORY--Table of Contents

 

                    Subpart A_Nonleaching Subcategory

 

Sec.  411.12  Effluent limitations guidelines representing the degree of 

effluent reduction attainable by the application of the best practicable 

control technology currently available.



    Except as provided in Sec. Sec.  125.30 through 125.32, any existing 

point source subject to this subpart shall achieve the following 

effluent limitations representing the degree of effluent reduction 

attainable by the application of the best practicable control technology 

currently available (BPT):



------------------------------------------------------------------------

                                          Effluent limitations (maximum

        Effluent characteristic                  for any 1 day)

------------------------------------------------------------------------

                                        Metric units (kg/kkg of product)

                                       ---------------------------------

TSS...................................  0.005.

Temperature (heat)....................  Not to exceed 3 [deg]C rise

                                         above inlet temperature.

pH....................................  Within the range 6.0 to 9.0.

                                       ---------------------------------

                                          English units (lb/1,000 lb of

                                                     product)

                                       ---------------------------------

TSS...................................  0.005.

Temperature (heat)....................  Not to exceed 3 [deg]C rise

                                         above inlet temperature.

pH....................................  Within the range 6.0 to 9.0.

------------------------------------------------------------------------





[39 FR 6591, Feb. 20, 1974, as amended at 60 FR 33950, June 29, 1995]



[[Page 193]]