[Code of Federal Regulations]

[Title 40, Volume 28]

[Revised as of July 1, 2006]

From the U.S. Government Printing Office via GPO Access

[CITE: 40CFR411.15]



[Page 193]

 

                   TITLE 40--PROTECTION OF ENVIRONMENT

 

         CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)

 

PART 411_CEMENT MANUFACTURING POINT SOURCE CATEGORY--Table of Contents

 

                    Subpart A_Nonleaching Subcategory

 

Sec.  411.15  Standards of performance for new sources.



    The following standards of performance establish the quantity or 

quality of pollutants or pollutant properties, controlled by this 

section, which may be discharged by a new source subject to the 

provisions of this subpart:



------------------------------------------------------------------------

                                          Effluent limitations (maximum

        Effluent characteristic                  for any 1 day)

------------------------------------------------------------------------

                                        Metric units (kg/kkg of product)

                                       ---------------------------------

TSS...................................  0.005.

Temperature (heat)....................  Not to exceed 3 [deg]C rise

                                         above inlet temperature.

pH....................................  Within the range 6.0 to 9.0.

                                       ---------------------------------

                                          English units (lb/1,000 lb of

                                                     product)

                                       ---------------------------------

TSS...................................  0.005.

Temperature (heat)....................  Not to exceed 3 [deg]C rise

                                         above inlet temperature.