[Code of Federal Regulations] [Title 40, Volume 28] [Revised as of July 1, 2006] From the U.S. Government Printing Office via GPO Access [CITE: 40CFR415.92] [Page 259-260] TITLE 40--PROTECTION OF ENVIRONMENT CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PART 415_INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY--Table of Contents Subpart I_Hydrogen Peroxide Production Subcategory Sec. 415.92 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT). (a) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart and manufacturing hydrogen peroxide by the oxidation of alkyl hydroanthraquinones must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): Subpart I--Hydrogen Peroxide Organic Process ------------------------------------------------------------------------ BPT limitations --------------------------- Average of Pollutant or pollutant property daily values Maximum for for 30 any 1 day consecutive days ------------------------------------------------------------------------ Kg/kkg (or pounds per 1,000 lb) of product --------------------------- TSS......................................... 0.80 0.40 TOC......................................... 0.44 0.22 pH.......................................... (\1\) (\1\) ------------------------------------------------------------------------ \1\ Within the range 6.0 to 9.0. (b) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart and manufacturing hydrogen peroxide by the electrolytic process must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): [[Page 260]] Subpart I--Hydrogen Peroxide Electrolyte Process ------------------------------------------------------------------------ BPT limitations --------------------------- Average of Pollutant or pollutant property daily values Maximum for for 30 any 1 day consecutive days ------------------------------------------------------------------------ Kg/kkg (or pounds per 1,000 lb) of product --------------------------- TSS......................................... 0.0050 0.0025 Cyanide A................................... 0.00040 0.00020 pH.......................................... (\1\) (\1\) ------------------------------------------------------------------------ \1\ Within the range 6.0 to 9.0. Subpart J--Nitric Acid Production Subcategory [Reserved]