[Code of Federal Regulations]

[Title 40, Volume 28]

[Revised as of July 1, 2006]

From the U.S. Government Printing Office via GPO Access

[CITE: 40CFR419.14]



[Page 358-359]

 

                   TITLE 40--PROTECTION OF ENVIRONMENT

 

         CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)

 

PART 419_PETROLEUM REFINING POINT SOURCE CATEGORY--Table of Contents

 

                      Subpart A_Topping Subcategory

 

Sec.  419.14  Effluent limitations guidelines representing the degree of 

effluent reduction attainable by the application of the best conventional 

pollutant control technology (BCT).



    (a) Any existing point source subject to this subpart must achieve 

the following effluent limitations representing the degree of effluent 

reduction attainable by the application of the best conventional 

pollutant control technology (BCT).



------------------------------------------------------------------------

                                                BCT effluent limitations

                                              --------------------------

                                                             Average of

                                                            daily values

       Pollutant or pollutant property         Maximum for     for 30

                                                any 1 day    consecutive

                                                             days shall

                                                             not exceed

------------------------------------------------------------------------

                                                Metric units (Kilograms

                                                   per 1,000 m\3\ of

                                                       feedstock)

                                              --------------------------

BOD5.........................................         22.7         12.0

TSS..........................................         15.8         10.1

Oil and Grease...............................          6.9          3.7

pH...........................................        (\1\)      (\1\)

                                              --------------------------

                                               English units (pounds per

                                                1,000 bbl of feedstock)

                                              --------------------------

BOD5.........................................          8.0          4.25

TSS..........................................          5.6          3.6

Oil and Grease...............................          2.5          1.3

P\H\.........................................        (\1\)      (\1\)

------------------------------------------------------------------------

\1\ Within the range of 6.0 to 9.0.



    (b) The limits set forth in paragraph (a) of this section are to be 

multiplied by the following factors to calculate the maximum for any one 

day and maximum average of daily values for thirty consecutive days.

    (1) Size factor.



------------------------------------------------------------------------

           1,000 bbl of feedstock per stream day             Size factor

------------------------------------------------------------------------

Less than 24.9.............................................         1.02

25.0 to 49.9...............................................         1.06

50.0 to 74.9...............................................         1.16

75.0 to 99.9...............................................         1.26

100 to 124.9...............................................         1.38

125.0 to 149.9.............................................         1.50

150.0 or greater...........................................         1.57

------------------------------------------------------------------------



    (2) Process factor.



------------------------------------------------------------------------

                                                               Process

                   Process configuration                        factor

------------------------------------------------------------------------

Less than 2.49.............................................         0.62

2.5 to 3.49................................................         0.67

3.5 to 4.49................................................         0.80

4.5 to 5.49................................................         0.95

5.5 to 5.99................................................         1.07

6.0 to 6.49................................................         1.17

6.5 to 6.99................................................         1.27

7.0 to 7.49................................................         1.39

7.5 to 7.99................................................         1.51

8.0 to 8.49................................................         1.64

8.5 to 8.99................................................         1.79

9.0 to 9.49................................................         1.95

9.5 to 9.99................................................         2.12

10.0 to 10.49..............................................         2.31

10.5 to 10.99..............................................         2.51

11.0 to 11.49..............................................         2.73

11.5 to 11.99..............................................         2.98

12.0 to 12.49..............................................         3.24

12.5 to 12.99..............................................         3.53

13.0 to 13.49..............................................         3.84

13.5 to 13.99..............................................         4.18

14.0 or greater............................................         4.36

------------------------------------------------------------------------



    (3) See the comprehensive example in subpart D, Sec.  419.43(b)(3).

    (c) The following allocations constitute the quantity and quality of 

pollutants or pollutant properties controlled by this paragraph and 

attributable to ballast, which may be discharged after the application 

of best conventional pollutant control technology by a point source 

subject to this subpart, in addition to the discharge allowed by 

paragraph (b) of this section. The allocation allowed for ballast water 

flow, as kg/cu m (lb/1000 gal), shall be based on those ballast waters 

treated at the refinery.



------------------------------------------------------------------------

                                               BCT Effluent limitations

                                                   for ballast water

                                             ---------------------------

                                                             Average of

       Pollutant or pollutant property                      daily values

                                               Maximum for     for 30

                                                any 1 day    consecutive

                                                             days shall

                                                             not exceed

------------------------------------------------------------------------

                                                Metric units (kilograms

                                                   per m\3\ of flow)

                                             ---------------------------

BOD5........................................         0.048         0.026

TSS.........................................         0.033         0.021

Oil and grease..............................         0.015         0.008

pH..........................................     (\1\)         (\1\)

                                             ---------------------------



[[Page 359]]





                                               English units (pounds per

                                                 1000 gallons of flow)

                                             ---------------------------

BOD5........................................         0.40          0.21

TSS.........................................         0.26          0.17

Oil and grease..............................         0.126         0.067

pH..........................................     (\1\)         (\1\)

------------------------------------------------------------------------

\1\ Within the range of 6.0 to 9.0.



    (d) The quantity and quality of pollutants or pollutant properties 

controlled by this paragraph attributable to once-through cooling water, 

are excluded from the discharge allowed by paragraph (b) of this 

section.

    (e) Effluent limitations for contaminated runoff. The following 

effluent limitations constitute the quantity and quality of pollutants 

or pollutant properties controlled by this paragraph and attributable to 

contaminated runoff which may be discharged after the application of the 

best conventional pollutant control technology by a point source subject 

to this subpart.

    (1) If wastewater consists solely of contaminated runoff and is not 

commingled or treated with process wastewater, it may be discharged if 

it does not exceed 15 mg/l oil and grease based upon an analysis of any 

single grab or composite sample.

    (2) If contaminated runoff is commingled or treated with process 

wastewater, or if wastewater consisting solely of contaminated runoff 

which exceeds 15 mg/l oil and grease is not commingled or treated with 

any other type of wastewater, the quantity of pollutants discharged 

shall not exceed the quantity determined by multiplying the flow of 

contaminated runoff as determined by the permit writer times the 

concentrations listed in the following table:



------------------------------------------------------------------------

                                               BCT effluent limitations

                                                for contaminated runoff

                                             ---------------------------

                                                             Average of

       Pollutant or pollutant property                      daily values

                                               Maximum for     for 30

                                                any 1 day    consecutive

                                                             days shall

                                                             not exceed

------------------------------------------------------------------------

                                                Metric units (kilograms

                                               per 1,000 (m\3\ of flow)

                                             ---------------------------

BOD5........................................         48.          26.

TSS.........................................         33.          21.

Oil and grease..............................         15.           8.

pH..........................................      (\1\)        (\1\)

                                             ---------------------------

                                               English units (pounds per

                                                1,000 gallons of flow)

                                             ---------------------------

BOD5........................................          0.40         0.22

TSS.........................................          0.28         0.18

Oil and grease..............................          0.13         0.067

pH..........................................      (\1\)        (\1\)

------------------------------------------------------------------------

\1\ Within the range of 6.0 to 9.0.