[Code of Federal Regulations]

[Title 40, Volume 28]

[Revised as of July 1, 2006]

From the U.S. Government Printing Office via GPO Access

[CITE: 40CFR420.17]



[Page 397]

 

                   TITLE 40--PROTECTION OF ENVIRONMENT

 

         CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)

 

PART 420_IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY--Table of 

Contents

 

                    Subpart A_Cokemaking Subcategory

 

Sec.  420.17  Effluent limitations representing the degree of effluent 

reduction attainable by the application of the best conventional 

technology (BCT).



    Except as provided in 40 CFR 125.30 through 125.32, any existing 

point source subject to this subpart must achieve the following effluent 

limitations representing the degree of effluent reduction attainable by 

the application of the best conventional technology.

    (a) By-product cokemaking--iron and steel.



                                Subpart A

------------------------------------------------------------------------

                                                       BCT effluent

                                                       limitations

                                                ------------------------

                                                              Average of

        Pollutant or pollutant property                         daily

                                                   Maximum    values for

                                                  for any 1       30

                                                     day     consecutive

                                                                 days

------------------------------------------------------------------------

                                                    Kg/kkg (pounds per

                                                   1,000 lb) of product

                                                ------------------------

TSS............................................      0.253        0.131

O&G............................................      0.0327       0.0109

pH.............................................  (\1\)        (\1\)

------------------------------------------------------------------------

\1\ Within the range of 6.0 to 9.0.



    (1) Increased loadings, not to exceed 11 percent of the above 

limitations, are allowed for by-product coke plants which have wet 

desulfurization systems but only to the extent such systems generate an 

increased effluent volume.

    (2) Increased loadings, not to exceed 27 percent of the above 

limitations, are allowed for by-product coke plants which include 

indirect ammonia recovery systems but only to the extent that such 

systems generate an increased effluent volume.

    (b) By-product cokemaking--merchant.



                                Subpart A

------------------------------------------------------------------------

                                                       BCT effluent

                                                       limitations

                                                ------------------------

                                                              Average of

        Pollutant or pollutant property                         daily

                                                   Maximum    values for

                                                  for any 1       30

                                                     day     consecutive

                                                                 days

------------------------------------------------------------------------

                                                    Kg/kkg (pounds per

                                                   1,000 lb) of product

                                                ------------------------

TSS............................................      0.270        0.140

O&G............................................      0.0348       0.0116

pH.............................................  (\1\)        (\1\)

------------------------------------------------------------------------

\1\ Within the range of 6.0 to 9.0.



    (1) Increased loadings, not to exceed 10 percent of the above 

limitations, are allowed for by-product coke plants which have wet 

desulfurization systems but only to the extent such systems generate an 

increased effluent volume.

    (2) Increased loadings, not to exceed 25 percent of the above 

limitations, are allowed for by-product coke plants which include 

indirect ammonia recovery systems but only to the extent that such 

systems generate an increased effluent volume.

    (c) Cokemaking--non-recovery. Except as provided in 40 CFR 125.30 

through 125.32, any existing point source subject to this segment must 

achieve the following effluent limitations representing the degree of 

effluent reduction attainable by the application of the best 

conventional pollutant control technology (BCT): There shall be no 

discharge of process wastewater pollutants to waters of the U.S.



[47 FR 23284, May 27, 1982, as amended at 67 FR 64264, Oct. 17, 2002]