[Code of Federal Regulations]

[Title 40, Volume 12]

[Revised as of July 1, 2006]

From the U.S. Government Printing Office via GPO Access

[CITE: 40CFR63.1544]



[Page 97]

 

                   TITLE 40--PROTECTION OF ENVIRONMENT

 

         CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)

 

PART 63_NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR 

SOURCE CATEGORIES--Table of Contents

 

Subpart TTT_National Emission Standards for Hazardous Air Pollutants for 

                          Primary Lead Smelting

 

Sec.  63.1544  Standards for fugitive dust sources.



    (a) Each owner or operator of a primary lead smelter shall prepare, 

and at all times operate according to, a standard operating procedures 

manual that describes in detail the measures that will be put in place 

to control fugitive dust emissions from the sources listed in paragraphs 

(a)(1) through (a)(5) of this section:

    (1) Plant roadways;

    (2) Material storage and handling area(s);

    (3) Sinter machine area(s);

    (4) Furnace area(s); and

    (5) Refining and casting area(s).

    (b) Not withstanding paragraph (c) of this section, the standard 

operating procedures manual shall be submitted to the Administrator or 

delegated authority for review and approval.

    (c) Existing manuals that describe the measures in place to control 

fugitive dust sources required as part of a State implementation plan 

for lead shall satisfy the requirements of paragraph (a) of this section 

provided they address the sources listed in paragraphs (a)(1) through 

(a)(5) of this section.