[Code of Federal Regulations]
[Title 46, Volume 3]
[Revised as of October 1, 2006]
From the U.S. Government Printing Office via GPO Access
[CITE: 46CFR77.30-10]

[Page 91]
 
                           TITLE 46--SHIPPING
 
   CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED)
 
PART 77_VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT--Table 
of Contents
 
                    Subpart 77.30_Emergency Equipment
 
Sec.  77.30-10  Stowage.

    (a) The equipment set forth in table 77.30-10(a), together with such 
other items as the master may deem necessary, shall be stowed in 
convenient, accessible locations for use in case of emergency.

                                                Table 77.30-10(a)
----------------------------------------------------------------------------------------------------------------
                                                                                          Self-
                                                                            Self-       contained
                                                Number of passenger       contained     breathing       Flame
                 Service                            staterooms            breathing   apparatus for     safety
                                                                          apparatus   refrigeration     lamps
                                                                                           \1\
----------------------------------------------------------------------------------------------------------------
Ocean and coastwise, not on an             0 to 49                       ...........             1   ...........
 international voyage.
                                           50 to 100                               4             1   ...........
                                           Over 100                                6             1             1
Great Lakes, and lakes, bays, and sounds.  0 to 49                       ...........             1   ...........
                                           50 to 100                               2             1   ...........
                                           Over 100                                4             1             1
Rivers...................................  0 to 49                       ...........             1   ...........
                                           50 to 100                               1             1   ...........
                                           Over 100                                2             1             1
----------------------------------------------------------------------------------------------------------------
\1\ Required only on vessels equipped with any refrigeration unit using ammonia to refrigerate any space with a
  volume of more than 20 cubic feet or with any refrigeration unit using fluorocarbons to refrigerate any space
  with a volume of more than 1000 cubic feet.

    (b) If a separate self-contained breathing apparatus is maintained 
for protection against gas leaking from a refrigeration unit, it must be 
stowed convenient to, but outside of, the spaces containing the 
refrigeration equipment.
    (c) Half of the remaining equipment set forth in table 77.30-10(a) 
shall be stowed in or near the pilothouse together with a fire axe and 
the hand portable fire extinguishers required by table 76.50-10(a) for 
that location. The other half of the equipment shall be stowed in a 
convenient accessible location, remote from the pilothouse, and 
preferably adjacent to the main entrance to the machinery space. Where 
only one of an item is required, it shall be stowed in the pilothouse.

[CGFR 65-50, 30 FR 16953, Dec. 30, 1965, as amended by CGD 86-036, 57 FR 
48324, Oct. 23, 1992]