[Code of Federal Regulations]

[Title 47, Volume 1]

[Revised as of October 1, 2006]

From the U.S. Government Printing Office via GPO Access

[CITE: 47CFR15.213]



[Page 885]

 

                       TITLE 47--TELECOMMUNICATION

 

              CHAPTER I--FEDERAL COMMUNICATIONS COMMISSION

 

PART 15_RADIO FREQUENCY DEVICES--Table of Contents

 

                     Subpart C_Intentional Radiators

 

Sec.  15.213  Cable locating equipment.



    An intentional radiator used as cable locating equipment, as defined 

in Sec.  15.3(d), may be operated on any frequency within the band 9-490 

kHz, subject to the following limits: Within the frequency band 9 kHz, 

up to, but not including, 45 kHz, the peak output power from the cable 

locating equipment shall not exceed 10 watts; and, within the frequency 

band 45 kHz to 490 kHz, the peak output power from the cable locating 

equipment shall not exceed one watt. If provisions are made for 

connection of the cable locating equipment to the AC power lines, the 

conducted limits in Sec.  15.207 also apply to this equipment.