Sec.  15.35  Measurement detector functions and bandwidths.



    The conducted and radiated emission limits shown in this part are 

based on the following, unless otherwise specified elsewhere in this 

part:

    (a) On any frequency or frequencies below or equal to 1000 MHz, the 

limits shown are based on measuring equipment employing a CISPR quasi-

peak detector function and related measurement bandwidths, unless 

otherwise specified. The specifications for the measuring instrument 

using the CISPR quasi-peak detector can be found in Publication 16 of 

the International Special Committee on Radio Interference (CISPR) of the 

International Electrotechnical Commission. As an alternative to CISPR 

quasi-peak measurements, the responsible party, at its option, may 

demonstrate compliance with the emission limits using measuring 

equipment employing a peak detector function, properly adjusted for such 

factors as pulse desensitization, as long as the same bandwidths as 

indicated for CISPR quasi-peak measurements are employed.



    Note: For pulse modulated devices with a pulse-repetition frequency 

of 20 Hz or less and for which CISPR quasi-peak measurements are 

specified, compliance with the regulations shall be demonstrated using 

measuring equipment employing a peak detector function, properly 

adjusted for such factors as pulse desensitization, using the same 

measurement bandwidths that are indicated for CISPR quasi-peak 

measurements.



    (b) Unless otherwise specified, on any frequency or frequencies 

above 1000 MHz, the radiated emission limits are based on the use of 

measurement instrumentation employing an average detector function. 

Unless otherwise specified, measurements above 1000 MHz shall be 

performed using a minimum resolution bandwidth of 1 MHz. When average 

radiated emission measurements are specified in this part, including 

average emission measurements below 1000 MHz, there also is a limit on 

the peak level of the radio frequency emissions. Unless otherwise 

specified, e.g., see Sec. Sec.  15.250, 15.252, 15.255, and 15.509-

15.519, the limit on peak radio frequency emissions is 20 dB above the 

maximum permitted average emission limit applicable to the equipment 

under test. This peak limit applies to the total peak emission level 

radiated by the device, e.g., the total peak power level. Note that the 

use of a pulse desensitization correction factor may be needed to 

determine the total peak emission level. The instruction manual or 

application note for the measurement instrument should be consulted for 

determining pulse desensitization factors, as necessary.

    (c) Unless otherwise specified, e.g. Sec.  15.255(b), when the 

radiated emission limits are expressed in terms of the average value of 

the emission, and pulsed operation is employed, the measurement field 

strength shall be determined by averaging over one complete pulse train, 

including blanking intervals, as long as the pulse train does not exceed 

0.1 seconds. As an alternative (provided the transmitter operates for 

longer than 0.1 seconds) or in cases where the pulse train exceeds 0.1 

seconds, the measured field strength shall be determined from the 

average absolute voltage during a 0.1 second interval during which the 

field strength is at its maximum value. The exact method of calculating 

the average field strength shall be submitted with any application for 

certification or shall be retained in the measurement data file for 

equipment subject to notification or verification.



[54 FR 17714, Apr. 25, 1989, as amended at 56 FR 13083, Mar. 29, 1991; 

61 FR 14502, Apr. 2, 1996; 63 FR 42279, Aug. 7, 1998; 67 FR 34855, May 

16, 2002; 70 FR 6773, Feb. 9, 2005]