[Code of Federal Regulations]
[Title 49, Volume 6]
[Revised as of October 1, 2006]
From the U.S. Government Printing Office via GPO Access
[CITE: 49CFR572.36]

[Page 933-934]
 
                        TITLE 49--TRANSPORTATION
 
                   CHAPTER V--NATIONAL HIGHWAY TRAFFIC
                    SAFETY ADMINISTRATION, DEPARTMENT
                            OF TRANSPORTATION
 
PART 572_ANTHROPOMORPHIC TEST DEVICES--Table of Contents
 
                     Subpart E_Hybrid III Test Dummy
 
Sec.  572.36  Test conditions and instrumentation.

    (a) The test probe used for thoracic impact tests is a 6 inch 
diameter cylinder that weighs 51.5 pounds including instrumentation. Its 
impacting end has a flat right angle face that is rigid and has an edge 
radius of 0.5 inches. The test probe has an accelerometer mounted on the 
end opposite from impact with its sensitive axis colinear to the 
longitudinal centerline of the cylinder.
    (b) Test probe used for the knee impact tests is a 3 inch diameter 
cylinder that weights 11 pounds including instrumentation. Its impacting 
end has a flat right angle face that is rigid and has an edge radius of 
0.02 inches. The test probe has an accelerometer mounted on the end 
opposite from impact with its sensitive axis colinear to

[[Page 934]]

the longitudinal centerline of the cylinder.
    (c) Head accelerometers shall have dimensions and response 
characteristics specified in drawing 78051-136, revision A, or its 
equivalent, and the location of their seismic mass as mounted in the 
skull are shown in drawing C-1709, revision D.
    (d) The six axis neck transducer shall have the dimensions, response 
characteristics, and sensitive axis locations specified in drawing C-
1709, revision D and be mounted for testing as shown in Figures 20 and 
21 of Sec.  572.33, and in the assembly drawing 78051-218, revision T.
    (e) The chest accelerometers shall have the dimensions, response 
characteristics, and sensitive mass locations specified in drawing 
78051-136, revision A or its equivalent and be mounted as shown with 
adaptor assembly 78051-116, revision D for assembly into 78051-218, 
revision T.
    (f) The chest deflection transducer shall have the dimensions and 
response characteristics specified in drawing 78051-342, revision A or 
its equivalent and be mounted in the chest deflection transducer 
assembly 78051-317, revision A for assembly into 78051-218, revision T.
    (g) The thorax and knee impactor accelerometers shall have the 
dimensions and characteristics of Endevco Model 7231c or equivalent. 
Each accelerometer shall be mounted with its sensitive axis colinear 
with the pendulum's longitudinal centerline.
    (h) The femur load cell shall have the dimensions, response 
characteristics, and sensitive axis locations specified in drawing 
78051-265 or its equivalent and be mounted in assemblies 78051-46 and -
47 for assembly into 78051-218, revision T.
    (i) The outputs of acceleration and force-sensing devices installed 
in the dummy and in the test apparatus specified by this part are 
recorded in individual data channels that conform to requirements of 
Society of Automotive Engineers (SAE) Recommended Practice J211 Mar95, 
Instrumentation for Impact Tests, Parts 1 and 2. SAE J211 Mar95 sets 
forth the following channel classes:
    (1) Head acceleration--Class 1000
    (2) Neck forces--Class 1000
    (3) Neck moments--Class 600
    (4) Neck pendulum acceleration--Class 60
    (5) Thorax and thorax pendulum acceleration--Class 180
    (6) Thorax deflection--Class 180
    (7) Knee pendulum acceleration--Class 600
    (8) Femur force--Class 600
    (j) Coordinate signs for instrumentation polarity conform to the 
sign convention shown in the document incorporated by Sec.  
572.31(a)(5).
    (k) The mountings for sensing devices shall have no resonance 
frequency within range of 3 times the frequency range of the applicable 
channel class.
    (l) Limb joints are set at lg, barely restraining the weight of the 
limb when it is extended horizontally. The force required to move a limb 
segment shall not exceed 2g throughout the range of limb motion.
    (m) Performance tests of the same component, segment, assembly, or 
fully assembled dummy are separated in time by period of not less than 
30 minutes unless otherwise noted.
    (n) Surfaces of dummy components are not painted except as specified 
in this part or in drawings subtended by this part.

[51 FR 26701, July 25, 1986, as amended at 53 FR 8765, Mar. 17, 1988; 62 
FR 27518, May 20, 1997; 63 FR 45965, Aug. 28, 1998]