    Ultraviolet radiation for the processing and treatment of food may 
be safely used under the following conditions:
    (a) The radiation sources consist of low pressure mercury lamps 
emitting 90 percent of the emission at a wavelength of 253.7 nanometers 
(2,537 Angstroms).

[[Page 455]]

    (b) The ultraviolet radiation is used or intended for use as 
follows:

----------------------------------------------------------------------------------------------------------------
             Irradiated food                              Limitations                            Use
----------------------------------------------------------------------------------------------------------------
Food and food products...................  Without ozone production: high fat-       Surface microorganism
                                            content food irradiated in vacuum or in   control.
                                            an inert atmosphere; intensity of
                                            radiation, 1 W (of 2,537 A. radiation)
                                            per 5 to 10 ft.\2\.
Potable water............................  Without ozone production; coefficient of  Sterilization of water used
                                            absorption, 0.19 per cm or less; flow     in food production.
                                            rate, 100 gal/h per watt of 2,537 A.
                                            radiation; water depth, 1 cm or less;
                                            lamp-operating temperature, 36 to 46
                                            [deg]C..
Juice products...........................  Turbulent flow through tubes with a       Reduction of human
                                            minimum Reynolds number of 2,200..        pathogens and other
                                                                                      microorganisms.
----------------------------------------------------------------------------------------------------------------


[42 FR 14635, Mar. 15, 1977, as amended at 65 FR 71057, Nov. 29, 2000]